INSTALLATION INSTRUCTIONS

SPECIFICATIONS

See "Specifications" on page 18.

UNPACKING

Undo straps, lift carton off heater.
Never lift heater out of carton by top louvres.
Check for damage. If the heater is damaged contact your supplier or Rinnai for advice BEFORE INSTALLATION.

INCLUDED IN CARTON

Refer to "Carton Contents / Item Checklist" on page 10.

BEFORE INSTALLATION

Remove and discard all packing materials.

BEFORE USING THE HEATER

Check heater supplied is correct for gas type in your area.
Refer to local Gas Authority for confirmation of gas type if in doubt. Gas type is indicated on the data plate.
Check room size and ventilation
This heater must not be installed in a room smaller than 125m
Fixed ventilation must conform to local regulations.
Number and position of vents is for illustrative purposes only. For more information on ventilation, please refer
to the Rinnai website on www.rinnai.com.au
DO NOT install in a bedroom or bathroom.
The bayonet plug on the factory fitted flexible hose simply plugs into your bayonet fitting.
For this heater, room size H x W x D must equal or exceed 125.0 m
For example: if room size is L 7.5m x W 7m x H 2.4m the volume will be 126.0m