CARE OF THE HEATER
Your Cosypanel needs very little maintenance,
but the following
information will help you keep it looking good, and working efficiently.
l
Unplug unit before cleaning
l
All parts of the heater can be cleaned using a soft, damp cloth.
l
Do not use solvents to clean any parts.
l
Do not spray aerosols in the vicinity of this appliance while it is in
operation.
l
Do not place articles on or against this appliance.
l
Do not store flammable materials near this appliance.
Service
The internal gas controls are factory set and in normal circumstances will
not require any adjustment in service. If however the unit fails or requires
attention then any approved Rinnai Service Centre or Gas Utility should be
contacted.
NOTE:
Servicing may only be undertaken by an authorised person
Rinnai recommends your Cosypanel is checked and serviced
annually.
INSTALLATION INSTRUCTIONS
Unoack Heater
Preferably undo bottom of carton, place carton correct way up, then lift
carton off the heater. Never lift the heater by its top louvres. Check for
damage. If unit is damaged, contact your Supplier for advice. Before
installing the heater, check unit is labelled for the correct gas type.
Included in Carton
Customer's instructions.
Wall mounting bracket.
IMPORTANT
1. The appliance must be installed to the requirements
of the local gas
authority.
2.
Do not fix in close proximity to curtains or other combustible
materials.
4
2
2:
7.
8.
9.
For information on gas rate, see data plate on the appliance.
When installing this appliance, ensure that the room is correctly
ventilated.
Do not install in bedroom or bathroom.
This appliance is fitted with variable control and the burner can be
operated at any setting between high and min.
The recommended
clearance for installation is 1OOmm from the floor
and 150mm clearance from either of the side panels.
Do not install heater under a shelf, mantlepiece or other projection
within a distance of 800 mm from top of heater.
Do not install heater under a window.
_ .
10. This unit is not designed to be built in.
11. This heater has been designed for convenient wall mounting using the
mounting bracket provided.
NOTE:
MINIMUM
ROOM
SIZE REQUIREMENT
RSOOT / TF
42 Cu Metres
R501T / TF
29 Cu Metres
In halls, passages and shops where ventilation is greater than normally
obtainable in living rooms, it shall be permissible to increase continuous
heat input to 0.4 MJ/h per cubic metre of enclosed space.
INLET CONNECTION
The inlet to the heater is a 3/8" B.S.P. flare fitting with nut and will fit
1Omm O.D. copper pipe. It is situated 103mm from the right hand end of
the heater and 42mm from the rear of the heater.
INSTALLATION
The rear panel incorporates
a combined wall spacer and mounting bracket
extending the full width of the heater. The wall mounting bracket is
supplied taped to the rear of the heater. To maintain 1OOmm clearance
from the floor, the wall bracket should be screwed to the wall at 425mm
from the floor to the centre of the screw holes.
Position the heater on the wall bracket, then secure the heater to the wall
using the bracket provided on the underside of the base panel.
Do not remove the lower rubber wall spacers as these provide an air gap
between the heater and wall.