HP ProCurve Switch 2610 Series
Safety
Emissions
Immunity
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Power frequency magnetic field
Voltage dips and interruptions
Harmonics
Flicker
Management
Notes
Services
CSA 22.2 No. 60950; UL 60950; IEC 60950; EN 60950
FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
EN 55024, CISPR 24
IEC 61000-4-2; 4 kV CD, 8 kV AD
IEC 61000-4-3; 3V/m
IEC 61000-4-4; 1.0 kV(power line), 0.5kV (signal line)
IEC 61000-4-5; 1 kV/2 kV AC
IEC 61000-4-6; 3V
IEC 61000-4-8; 1A/m,50 or 60 Hz
IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25
periods
EN 61000-3-2, IEC 61000-3-2
EN 61000-3-3, IEC 61000-3-3
HP ProCurve Manager Plus; HP ProCurve Manager (included);
command-line interface; Web browser; configuration menu;
out-of-band management (serial RS-232C)
When using mini-GBICs with this product, mini-GBICs with revision
"B" or later (product ends with the letter "B" or later, e.g., J4858B,
J4859C) are required.
3-year, 4-hour onsite, 13x5 coverage for hardware (U4683E)
3-year, 4-hour onsite, 24x7 coverage for hardware (U4835E)
3-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software
phone support (U6321E)
3-year, 24x7 SW phone support, software updates (UF792E)
Installation with minimum configuration, system-based pricing
(U4826E)
Installation with HP-provided configuration, system-based pricing
(U4830E)
Refer to the HP Web site at
www.procurve.com/services
on the service-level descriptions and product numbers. For details
about services and response times in your area, please contact your
local HP sales office.
CSA 22.2 No. 60950; UL 60950; IEC 60950; EN 60950
FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
EN 55024, CISPR 24
IEC 61000-4-2; 4 kV CD, 8 kV AD
IEC 61000-4-3; 3V/m
IEC 61000-4-4; 1.0 kV(power line), 0.5kV (signal line)
IEC 61000-4-5; 1 kV/2 kV AC
IEC 61000-4-6; 3V
IEC 61000-4-8; 1A/m,50 or 60 Hz
IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25
periods
EN 61000-3-2, IEC 61000-3-2
EN 61000-3-3, IEC 61000-3-3
HP ProCurve Manager Plus; HP ProCurve Manager (included);
command-line interface; Web browser; configuration menu;
out-of-band management (serial RS-232C)
When using mini-GBICs with this product, mini-GBICs with revision
"B" or later (product ends with the letter "B" or later, e.g., J4858B,
J4859C) are required.
3-year, 4-hour onsite, 13x5 coverage for hardware (U4683E)
3-year, 4-hour onsite, 24x7 coverage for hardware (U4835E)
3-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software
phone support (U6321E)
3-year, 24x7 SW phone support, software updates (UF792E)
Installation with minimum configuration, system-based pricing
(U4826E)
Installation with HP-provided configuration, system-based pricing
(U4830E)
for details
Refer to the HP Web site at
on the service-level descriptions and product numbers. For details
about services and response times in your area, please contact your
local HP sales office.
www.procurve.com/services
for details
8