Download Print this page

HP AW563A Quickspecs page 35

Bladesystem c3000 enclosure

Advertisement

QuickSpecs
Technical Specifications
Option Kits
Option Kits
Option Kits
Option Kits
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature Operating
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
Altitude
Altitude
Altitude
Altitude
Acoustic Noise
Acoustic Noise
Acoustic Noise
Acoustic Noise
Power Supply Dimensions
Power Supply Dimensions
Power Supply Dimensions Size
Power Supply Dimensions
Fan Option Shipping
Fan Option Shipping
Fan Option Shipping
Fan Option Shipping
Dimensions
Dimensions
Dimensions
Dimensions
DA - 12790
Worldwide — Version 42 — November 14, 2011
Maximum Peak Power
Non-operating
Operating
Non-operating
Operating
Non-operating
Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
the product is operating in a 23°C ambient environment. Noise emissions
were measured in accordance with ISO 7779 (ECMA 74) and declared in
accordance with ISO 9296 (ECMA 109).
Idle
Operating
Weight
Size
Weight
HP BladeSystem c3000 Enclosure
HP BladeSystem c3000 Enclosure
HP BladeSystem c3000 Enclosure
HP BladeSystem c3000 Enclosure
880 W (at 100 VAC)
990 W (at 120 VAC)
1350 W (at 200 to 240 VAC)
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed. System performance may be reduced if
operating with a fan fault or above 30°C (86°F).
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non-
condensing.
3050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500 ft/min).
depends on server configuration & mix of server
blades
varies by CPU utilization, server configuration,
and mix of server blades
Height: 1.515 in (38.48 mm)
Width: 3.4 in (86.36 mm)
Depth: 7.5 in (190.5 mm)
2.5 lbs (1.13 kg)
Height: 8.75 in (223 mm)
Width: 9.75 in (248 mm)
Depth: 15.88 in (403 mm)
4.0 lbs (1.8 kg)