Download Print this page

MadgeTech UltraShock-EB-5 Product Information Card

Advertisement

Quick Links

Description
Channels
Shock (3 axes), Temperature, Humidity, Pressure
Range
Resolution
Accuracy
Sample Rate
Reading Rate
Memory
Required Interface Package
Baud Rate
Typical Battery Life
Operating Environment
-20 °C to +54 °C, 0 to 95%RH (non-condensing)
Material
Dimensions
5.5" x 5.4" x 3.2" (140 mm x 137 mm x 80 mm)
Weight
Approvals
*Acceleration Range, Resolution and Accuracy
Channel
Temperature
Range
-20 °C to +54 °C
Accuracy
+0.5 °C
Resolution
0.1 °C
*Shock Acceleration Range, Resolution and Accuracy
Shock Range
+5 g
Accuracy
+0.2 g
Resolution
0.01 g
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE,
FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY
LEAK OR EXPLODE IF HEATED ABOVE 54 °C (129 °F).
1.800.544.2843
UltraShock-EB
*See Tables Below
512 Hz
64Hz up to 5 minutes
174,762/channel
IFC200
115,200
60 days
Anodized aluminum
80 oz. (2.3 kg)
CE
Humidity
Pressure
0 to 95%RH
0 to 30PSIA
+3%RH
+1%FSR @ 25 °C
0.1%RH
0.002PSIA
+50 g
+100 g
+250 g
+1.0 g
+2.0 g
+4.0 g
0.03 g
0.05 g
0.2 g
www.calcert.com
10
15
20
5
25
0
30
Product Information Card
UltraShock-EB-5
Temperature, Humidity, Pressure, and Tri-axial +5g, Shock Data Logger
with Extended Battery Life
UltraShock-EB-50
Temperature, Humidity, Pressure, and Tri-axial +50g, Shock Data Logger
with Extended Battery Life
UltraShock-EB-100
Temperature, Humidity, Pressure, and Tri-axial +100g, Shock Data Logger with
Extended Battery Life
UltraShock-EB-250
Temperature, Humidity, Pressure, and Tri-axial +250g, Shock Data Logger with
Extended Battery Life
sales@calcert.com
UltraShock-EB
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289

Advertisement

loading

Summary of Contents for MadgeTech UltraShock-EB-5

  • Page 1 +0.5 °C +3%RH +1%FSR @ 25 °C Resolution 0.1 °C 0.1%RH 0.002PSIA UltraShock-EB-5 Temperature, Humidity, Pressure, and Tri-axial +5g, Shock Data Logger *Shock Acceleration Range, Resolution and Accuracy with Extended Battery Life Shock Range +5 g +50 g +100 g...
  • Page 2 UltraShock-EB Product Information Card Product Notes - The status of the device will change to “Running”, “Waiting to Start” or “Waiting to Reading Intervals Manual Start”, depending upon your start method. The UltraShock-EB measures pressure, temperature, humidity and tri-axial shock. The shock - Disconnect the data logger from the interface cable and place it in the environment to parameter samples at 512Hz and at the user specified reading rate, the device writes the measure.

This manual is also suitable for:

Ultrashock-ebUltrashock-eb-50Ultrashock-eb-100Ultrashock-eb-250