WIZ1000 User's Manual
(Version1.0)
©2009 WIZnet Co., Ltd. All Rights Reserved.
☞ For more information, visit our website at
http://www.wiznet.co.kr

Advertisement

Table of Contents
loading

Summary of Contents for Wiznet WIZ1000-EU

  • Page 1 WIZ1000 User’s Manual (Version1.0) ©2009 WIZnet Co., Ltd. All Rights Reserved. ☞ For more information, visit our website at http://www.wiznet.co.kr...
  • Page 2 WIZnet’s Online Technical Support If you want to know more about WIZnet products, please visit WIZnet website (www.wiznet.co.kr), and you could also put your questions on Q&A Board. Our engineers will reply you as soon as possible. Copyright © WIZnet All Rights Reserved...
  • Page 3 Document Revision History Date Revision Changes 2009-06-26 V1.0 First Release Copyright Notice Copyright 2009 WIZnet, Inc. All Rights Reserved. Technical Support: support@wiznet.co.kr Sales & Distribution: sales@wiznet.co.kr For more information, please visit our website: http://www.wiznet.co.kr Copyright © WIZnet All Rights Reserved...
  • Page 4 Trade Name or Applicant : WIZnet, Inc. Equipment Name : Serial to Ethernet Device Server Basic Model Number : WIZ1000 Manufacturer / Country of Origin : WIZnet, Inc. / KOREA Certification Number : WWW-WIZ1000-S2E(A) This equipment has been tested for a Class A digital device.
  • Page 5: Table Of Contents

    ESTING ERIAL TO THERNET UNCTION 7. WIZ1000 HARDWARE SPECIFICATION ............. 36 7.1..................36 ARAMETERS 7.2..................36 PECIFICATION 7.3............. 36 OARD IMENSIONS AND SSIGNMENT 8. WARRANTY ..................... 38 Copyright © WIZnet All Rights Reserved WIZ1000 | 5 page...
  • Page 6 Table 8. Serial Configuration Testing Process ..........29 Table 9 Telnet Com Port Options List ............32 Table 10. Testing Environment of WIZ1000 ..........34 Table 11. RS-232 PIN Assignment ............37 Copyright © WIZnet All Rights Reserved WIZ1000 | 6 page...
  • Page 7: Introduction

    1. Introduction WIZ1000 is one model of Serial to Ethernet Device Server which is one finished product of WIZnet with CE, FCC and KCC certifications. WIZ1000 acts as a gateway between RS-232 and Ethernet. It enables remote gauging, managing and control of a device through the network based on Ethernet and TCP/IP by connecting to the existing equipment with RS-232 serial interface.
  • Page 8: Specification

    Speed : up to 230Kbps Input Voltage DC 5V Power Consumption Under 200mA Temperature 0°C ~ 80°C (Operation), -40°C ~ 85°C (Storage) Humidity 10 ~ 90% Table 1. Specification of WIZ1000 Copyright © WIZnet All Rights Reserved WIZ1000 | 8 page...
  • Page 9: Products Contents

    5V Power Adaptor (Optional) Table 2. Products Contents ☞ If there is any missing item, contact to the shop where you purchased. ☞ The optional items should be purchased separately. Copyright © WIZnet All Rights Reserved WIZ1000 | 9 page...
  • Page 10: Wiz1000

    MCU. If any data is transmitted from Ethernet, it is received to the internal buffer of W5100, and sent to the serial port by MCU. MCU in the module controls the data according to the configuration value that user defined. Copyright © WIZnet All Rights Reserved WIZ1000 | 10 page...
  • Page 11: Configuration Tool

    Therefore, just use this mode only for Debug mode. ⓒ Board List : If you click “Search” button, all the MAC addresses on a same subnet, will be Copyright © WIZnet All Rights Reserved WIZ1000 | 11 page...
  • Page 12: Figure 3. Pppoe Connection Process In Serial Console

    --PHASE 3. PPPoE(ADSL) Authentication mode -- Authentication protocol : c223 00, --Waiting for PPPoE server’s admission -- ok --PHASE 4. IPCP process --ok Figure 3. PPPoE Connection Process in Serial Console Copyright © WIZnet All Rights Reserved WIZ1000 | 12 page...
  • Page 13: Figure 4. Tcp Server Mode

    IP and Port. Mixed modes supports both of Server and Client. The communication process of each mode is as below. <TCP server mode> Figure 4. TCP Server mode At the TCP Server mode, WIZ1000 waits for the connection requests. Copyright © WIZnet All Rights Reserved WIZ1000 | 13 page...
  • Page 14: Figure 5. Tcp Client Mode

    2. If the connection is complete, data can be transmitted in both directions – from the host to the WIZ1000 and from WIZ1000 to the host. Copyright © WIZnet All Rights Reserved WIZ1000 | 14 page...
  • Page 15: Figure 6. Udp Mode

    If server has dynamic IP address, but domain name, if you use DNS function, you do not need to configure server IP address whenever it’s changed. If module does not have valid network information, Direct IP search is not available. ☞ Copyright © WIZnet All Rights Reserved WIZ1000 | 15 page...
  • Page 16: Figure 7 Search Password Input Dialog

    The module will re-initialize with the changed configuration. Changed value is saved in the EEPROM of the module. Thus, the value is not removed even though power is disconnected. The configuration value can be changed in below steps. Copyright © WIZnet All Rights Reserved WIZ1000 | 16 page...
  • Page 17 ⑤ To check configuration result, click ‘Search’ button. ⓟ Upload Firmware will be uploaded through network ☞ After uploading the firmware, 20~30 seconds are required for initialization. ⓠ Exit : Close the configuration tool program. Copyright © WIZnet All Rights Reserved WIZ1000 | 17 page...
  • Page 18: Figure 8. Configuration Tool (Serial Config.)

    Therefore, the data can be regarded as error data due to inconsistent data length. In order to solve this problem, the data from serial can be packed according to Copyright © WIZnet All Rights Reserved WIZ1000 | 18 page...
  • Page 19 Any one of three conditions is satisfied, the data is transmitted to the Ethernet. Ex) Delimiter: Size=10, Char=0x0D Serial data: 0123456789abc Ethernet data: 0123456789 ☞ “abc” will be remained in the serial buffer of module. Copyright © WIZnet All Rights Reserved WIZ1000 | 19 page...
  • Page 20: Figure 9. Configuration Tool (Option Config.)

    If one system holds the connection to the WIZ1000, other systems cannot connect to the module. If there is no data transmission during the time defined in Inactivity time, the connection will be closed for other system to be connected. Copyright © WIZnet All Rights Reserved WIZ1000 | 20 page...
  • Page 21 EEPROM of WIZ1000, and it can be modified via this configuration tool. The password can be any alphabet or number. Its length can be variable and its maximum length is 8 bytes. The password is case sensitive and the default password is ‘wiznet’. ⓧ...
  • Page 22: Figure 10. Option Mode For Password Configuration

    The port of telnet and login password can also be defined by users. The maximum length of telnet login password is 8 bytes and its default password is ‘wiznet’. The default telnet port is Copyright © WIZnet All Rights Reserved...
  • Page 23: Firmware Upload

    Select a module shown in “Board list”, and click “Upload” button. ③ ☞ Before uploading through Ethernet, you should set the network information of WIZ1000 first by Configuration Tool program as shown above Fig 10. By using Ping test, Copyright © WIZnet All Rights Reserved WIZ1000 | 23 page...
  • Page 24: Figure 12. Open Dialog Box For Uploading

    The firmware uploading status will be pop up as shown in Figure 13. ⑤ Figure 13. Firmware uploading window ⑥ When the firmware is uploaded successfully, the following message will be shown. Figure 14. Firmware upgraded successfully Copyright © WIZnet All Rights Reserved WIZ1000 | 24 page...
  • Page 25: Serial Configuration

    Table 5. Serial Configuration STX & ETX Reply Code Reply Comments Command was successful Command failed Invalid STX Invalid command Invalid parameter Invalid ETX Enter serial command mode Table 6. Serial Configuration Reply Code Copyright © WIZnet All Rights Reserved WIZ1000 | 25 page...
  • Page 26 0~65535 Set Inactivity timer value MAC Address Get MAC Address 0 : Not Use, 1 : Use Check DNS Use or Not IP address DNS IP Check Domain Domain Check Copyright © WIZnet All Rights Reserved WIZ1000 | 26 page...
  • Page 27: Table 7. Serial Configuration Command Code

    0~65535 Get the server port number Get delimiter character in hex 0~255 Get delimiter size 0~65535 Get delimiter time 0~65535 Get Inactivity timer value Table 7. Serial Configuration Command Code Copyright © WIZnet All Rights Reserved WIZ1000 | 27 page...
  • Page 28: Wiz1000 Configuration With Erial Ommand

    ‘setting’ button. The defaut value of string is “+++”. ③ The testing can be processed as below, This testing is for checking module IP and changing it to another. Copyright © WIZnet All Rights Reserved WIZ1000 | 28 page...
  • Page 29: Figure 15 Serial Configuration Console Display

    Above process is shown in the serial console as below figure. WIZ1000 Ver.01.00 >Config socket : OK >Listen : OK <E><S><S192.168.11.3><S> WIZ1000 Ver. 01.00 >Config socket : OK >Listen : OK Figure 15 Serial Configuration Console Display Copyright © WIZnet All Rights Reserved WIZ1000 | 29 page...
  • Page 30: Telnet Com Port Options

    Please note the default login password of WIZ1000 is ‘wiznet’, and it can be modified through the option page by users. Once the “Start!” button is clicked, the “WILL” command will be sent to WIZ1000. If WIZ1000 Copyright ©...
  • Page 31: Figure 17 Telnet Com Port Option Client Tool Execution Example

    Table 9. For more detailed introduction of Telnet Com port options, please refer to RFC2217. Figure 17 User interface of Telnet Com Port Option Copyright © WIZnet All Rights Reserved WIZ1000 | 31 page...
  • Page 32: Table 9 Telnet Com Port Options List

    Set CTS signal state ON Set CTS signal state OFF Line State Mask Refer to RFC2217 Modem State Mask Refer to RFC2217 Purge Data Refer to RFC2217 Table 9 Telnet Com Port Options List Copyright © WIZnet All Rights Reserved WIZ1000 | 32 page...
  • Page 33 WIZ1000. An example of using Telnet Com Port Option Client program to communicate with WIZ1000 is shown in Figure 17. After connected with WIZ1000, the received responses of WIZ1000 are listed in the below textbox. Copyright © WIZnet All Rights Reserved WIZ1000 | 33 page...
  • Page 34: Demonstration And Test

    6.1. Hardware Interface Power Serial Cable Reset LAN Cable Figure 18. WIZ1000 Interface Install as below steps. STEP 1: By using RJ45 Ethernet cable, connect the WIZ1000 to the network. Copyright © WIZnet All Rights Reserved WIZ1000 | 34 page...
  • Page 35: Testing Serial To Ethernet Function

    STEP8: You can check “Ethernet to Serial” function by inputting some character in the screen of Network terminal and checking them in the serial terminal. Above function can be tested by Device Terminal program that WIZnet is providing. Figure 19. Device Terminal Copyright ©...
  • Page 36: Wiz1000 Hardware Specification

    62KByte (MCU Internal) SRAM 16KByte (MCU Internal) EEPROM 2KByte (MCU Internal) 7.3. Board Dimensions and Pin Assignment 7.3.1. Dimensions 90.5 87.5 11.5 22.5 11.5 67.5 25.0 22.5 11.5 Figure 20. WIZ1000 Dimension Copyright © WIZnet All Rights Reserved WIZ1000 | 36 page...
  • Page 37: Figure 21. Rj-45 Pin Assignment

    Receive Data Transmit Data EXT_GND External Power Ground (Internally shorted to GND) Ground Not connect Request To Send Clear To Send EXT_VCC External Power Input (5V) Table 11. RS-232 PIN Assignment Copyright © WIZnet All Rights Reserved WIZ1000 | 37 page...
  • Page 38: Warranty

    WIZnet warrants our products and its parts against defects in materials and workmanship under normal use for period of standard ONE(1) YEAR for the WIZ1000 board and labor warranty after the date of original retail purchase. During this period, WIZnet will repair or replace a defective products or part free of charge.
  • Page 39 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: WIZnet WIZ1000...
  • Page 40 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: WIZnet WIZ1000-EU...