Sensor; Table 16 : Dimensions And Weights - Din Flanges - BASI BFM921 User Manual

Electromagnetic flowmeter
Table of Contents

Advertisement

Electromagnetic Flowmeter BFM921

7.2.3 Sensor

In the table below are the dimensions of the sensor for compact version. In case of remote version add 120
millimetres to dimension "A" for cable gland and cable. Flanges in DIN version meet standard EN1092.
Flanges in ANSI version meet requirements of ANSI B 16.5 standard.
DN (mm)
PN (bar)
15
16
20
16
25
16
32
16
40
16
50
16
65
16
80
16
100
16
125
16
150
16
200
16
250
10
300
10
350
10
400
10
500
10
600
10
700
10
800
10
62
D (mm)
A (mm)
95
145
105
150
115
155
140
165
150
175
165
185
185
200
200
215
220
235
250
265
285
295
340
355
395
435
445
485
505
535
565
580
670
695
780
800
895
900
1015
1010
Table 16 : Dimensions and weights – DIN flanges
L (mm)
Weight (kg)
200
3
200
3,5
200
4
200
5
200
5
200
7
200
8,5
200
10
250
13
250
17
300
22
350
31
450
44
500
57
550
72
600
95
600
120
600
160
700
230
800
330