Check Burner Manifold Pressure - Frymaster FBR18LP Installation, Operation, Service, And Parts Manual

Gas rethermalizers
Table of Contents

Advertisement

Vent Tube
3. Pass a piece of ordinary binding wire (.052 inch diameter) through the tube to remove any
obstruction.
4. Remove the wire, then blow through the tube to ensure it is clear.
5. Reinstall tube and bend so that the opening is pointing downward.

Check Burner Manifold Pressure

Frymaster recommends that this task be performed by the local gas company or an
1. Ensure that the gas valve knob is in the OFF position.
2. Remove the pressure tap plug from the gas valve assembly and attach the fitting for a gas
pressure-measuring device to the tap.
Regulator Cap
3. Place the gas valve in the ON position. Place the controller power switch in the ON position.
When the burner lights and continues to burn, compare the indicated pressure to the table
below.
WARNING
authorized service technician only.
4-3
Pressure
Tap Plug

Advertisement