FBR18 & FBRA18 SERIES GAS RETHERMALIZERS

CHAPTER 3: OPERATING INSTRUCTIONS

3.1

Introduction

Mechanically, the FBR18 and FBRA18 rethermalizers are virtually identical, the only difference
being that the FBRA18 units have an automatic filling (AutoFill) feature. Both units use the same
digital temperature controller and mechanical timers.
In operation, a setpoint is programmed into the controller which then regulates burner firing to
maintain the water in the cookpot at the desired temperature. Six individual color-coded mechani-
cal timers allow different types or quantities of product to be rethermalized simultaneously. The
timers are equipped with an alarm to notify the operator that rethermalizing is complete. The prod-
uct baskets have color-coded handles that correspond to the timers to eliminate confusion.
3.2

FBR18/FBRA18 Digital Controller

Frymaster
O
FBR18/FBRA18 D
PERATING THE
Ensure the cookpot is filled with water before turning the controller on. "Dry firing"
will cause damage to the cookpot!
1. Turn the controller on by pressing the Power
ber will display for 4 seconds in the digital display then change to the last programmed setpoint
temperature.
Power
Switch
9 . 9
Temperature
or Setpoint
Adjustment
Display Switch
C
IGITAL
ONTROLLER
Celsius or
Digital
Fahrenheit
Display
Display Switch
C
9
9
Setpoint
Melt
Cycle
Arrows
Switch
WARNING
switch. The controller software version num-
3-1
Heating
Mode
Indicator