Summary of Contents for Ryobi AJP-2200GQ

  • Page 1 AJP-2200GQ 6987307-00 STD( ナンア ) 01-16...
  • Page 2 Self suction kit...
  • Page 3 5, 6 5, 6 凹 凸 close open...
  • Page 4 ( Attaching the Self Suction Kit ) 17-1 17-2 D (C)
  • Page 5 close open 90°...
  • Page 6 引く...
  • Page 8 The insulation of the electric cable should be faultless 9. Hose clamp and without any cracks. If the electric cable is damaged, it 10. Nozzle cleaning pin should be replaced by RYOBI authorized distributor. 11. Oil (100ml) 1. Oil nozzle Mains power supply connection 1 3. Water suction filter...
  • Page 9: Safety Devices

    Try to determine the cause of important components for the safety of the device. Only the fault. If the problem repeats itself, please contact RYOBI use spray handle hoses, fittings and couplings that are service centre.
  • Page 10: Operating The Unit

    . Attaching the hose joint to the water supply hose • Avoid excessive friction that could damage the spray (Fig.3) handle hose when moving around objects such as Loosen and remove the hose link from the hose joint (8). fences, blocks, or bricks. Insert the water supply hose (3) through the hose link.
  • Page 11: Suction Height

    When used as self-priming About Suction Height • Suction height (A) is the distance between the water Attaching the Self suction kit level (B) and the highest point of the water suction hose 1. Attaching the water suction filter to the water supply port. (C)when the water supply port (D) is below the water •...
  • Page 12 After Use Changing the Spray Direction (Fig.32) The spray handle neck rotates 90 degrees. 1. Turn the main switch (16) to the OFF position. The spray direction of the variable nozzle lance () can be . Remove the strainer () from the water supply. changed during operation.
  • Page 13: Maintenance And Storage

    Replace the pump oil (Fig.45, 46) • Rinse the detergent spraying attachment after use. WARNING! Any repair should always be made by RYOBI authorized As the pump and pump oil are hot immediately after distributor with genuine spare parts. operation, there is a danger of getting burnt. Replace the oil after cooling sufficiently.
  • Page 14: Cleaning Of Machine Vents

    Environmental protection . Fix the spray handle hose to the connection. Firmly insert the spray handle hose into the connection, Recycle unwanted materials instead of disposing and fix by inserting the fixing pin. of them as waste. All tools, hoses and packaging Pull the spray handle hose and check that it doesn’t should be sorted, taken to the local recycling come out.
  • Page 15: Troubleshooting

    Troubleshooting Fault Cause Remedy The plug is damaged. Check the plug and fuses to see if The machine does not run when the There is insufficient voltage. they are okay. ON/OFF switch and spray handle lever The pump is locked. Manually turn over the motor. are pressed.
  • Page 16 Troubleshooting When used as self-priming Fault Cause Remedy Strainer is not completely submerged M a k e s u r e t h a t t h e s t r a i n e r i s (Because the water source decreases completely submerged into the water.
  • Page 20 RYOBI tool (hereinafter called “the Product”), for which it was not designed, or is not suited is warranted by Ryobi (herein called “the and no repairs, alterations or modifications Company”) to be free from defects in material...