Frigidaire PCFI3668AF Installation Instructions Manual page 4

36 induction range
Hide thumbs Also See for PCFI3668AF:
Table of Contents

Advertisement

Available languages

Available languages

36" INDUCTION RANGE INSTALLATION INSTRUCTIONS
Cabinet clearances
E
914 mm
F
603 mm
G
178 mm
H
min. 914 mm
I
min. 457 mm
J
K
max. 330 mm
Clearance J can have the following values:
• J = 30" / 762 mm minimum clearance between
the top of the cooking surface and the bottom of
an unprotected wood or metal cabinet.
• J = 24" / 610 mm minimum when the bottom of
wood or metal cabinet is protected by not less
than 1/4-inch-thick flame-retardant millboard cov-
ered with not less than No. 28 MSG sheet steel,
0.015-inch-thick stainless steel, 0.024-inch-thick
aluminum, or 0.020-inch-thick copper. Clearances
from non-combustible materials are not part of the
ANSI Z21.1 scope and are not certified by CSA.
Clearances of less than 30'' should be approved
by the local codes and/or by the local authority
having jurisdiction.
36"
23" 3/4
7"
min. 36"
min. 18"
see notes below
max. 13"
The side cabinet depth (clearance F) must match
the front edge of the range side panel:
Location of the grounded outlet
The grounded outlet should be located in the high-
lighted area in the image above. This area must
have the following measures:
D
Min: 11" 7/8
Min: 11" 7/8
L
Max: 24" 2/8
Min: 2"
M
Max: 9" 7/8
4
Min: 300 mm
Min: 300 mm
Max: 614 mm
Min: 51 mm
Max: 250 mm

Advertisement

Chapters

Table of Contents
loading

Table of Contents