Hoshizaki IM-65NE Instruction Manual page 10

Self-contained cuber
Hide thumbs Also See for IM-65NE:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
* Water supply pressure should be minimum 0.07 MPa (0.7 bar) and maximum 0.78 MPa (8 bar). If the pressure exceeds 0.78
MPa (8 bar), use a proper pressure reducing valve. Do NOT throttle back the supply tap.
* A plumbing permit and services of a licensed plumber may be required in some areas.
* The icemaker drain is gravity flow, so ensure drain hose has an adequate pitch or fall.
* Drain lines should not be installed directly to the sewer system. A vertical air gap of a minimum of 5
cm should be between the end of the drain hoses from the icemaker and the floor drain.
* To prevent a backflow into the storage bin, the outlet hose must be laid as shown.
GOOD
Downgrade
* On water-cooled model, a back flow preventer may be required in the cooling water circuit.
* Be sure to use the new hose-sets supplied with the appliance. Do not reuse any old hose-sets.
[Air-Cooled Model]
1) Attach the angled end of flexible inlet hose
(accessory) to the G3/4 fitting on the rear of the
icemaker as indicated, ensuring rubber sealing
washer is correctly positioned. Hand tighten
sufficiently to provide leak free joint.
2) Attach the other end of inlet hose to the water tap,
noting washer is correctly positioned before hand
tightening as above. It is a wise precaution to
have a stop valve within easy reach.
3) [Except IM-100CNE]
Hand tighten grey flexible outlet hose (accessory)
onto the R3/4 fitting on the rear of the icemaker
as indicated, ensuring rubber washer is correctly
positioned to obtain a leak free joint. The hose
can be cut to length as necessary to suit position
of main drain.
[IM-100CNE]
By means of a suitable spanner or wrench, tighten
the 3/4-3/4 nipple (accessory) into the Rc3/4
fitting on the bottom of the icemaker as indicated.
P.T.F.E. tape and/or a suitable sealing compound
should be used to obtain a leak free joint.
Note: Jointing compounds should be approved and suitable for potable water use.
Hand tighten grey flexible outlet hose (accessory) onto the 3/4-3/4 nipple as indicated, ensuring rubber washer is correctly
positioned to obtain a leak free joint. The hose can be cut to length as necessary to suit position of main drain.
[Water-Cooled Model]
* Hoshizaki recommends that the water-cooled condenser should be connected to a closed circuit recirculating type cooling
system utilizing a tower, water chiller or similar. Water make up should be via a ball valve/break tank arrangement.
* Whilst connecting a water-cooled condenser to a mains water (potable) supply will not affect the performance of the machine,
it will most certainly cause a high use/waste of a valuable resource and is not recommended.
* The services of a licensed or coded plumber should be used to ensure a correct installation.
* The connections should be made properly in compliance with the applicable national or local regulations.
BAD
Upgrade
Air-Cooled Model
Inlet Hose
Outlet Hose
7
Floor
BAD
Potable Water
Inlet G3/4
Drain Outlet R3/4
IM-100CNE
ENGLISH
5cm air gap
Drain
Water Supply Tap
Inlet Hose
Drain Outlet Rc3/4
3/4-3/4 Nipple
Outlet Hose

Advertisement

Table of Contents
loading

Table of Contents