Download Print this page

NUTRICHEF PKBRTP99 User Manual page 2

Homebrew double wall mini keg beer dispenser

Advertisement

Wait for 2 mins, then pull on the pressure relieving ring
for a couple of seconds. This is for adjusting pressure of
keg beer.
5. Put a glass or pitcher under
the faucet spout, with the
faucet knob pulled forward
(ON), slowly turn the regulator
knob on in clockwise direction,
until beer starts to ow out.
Don't continue adding
pressure, suggest tapping 5-8
PSI (Max pressure 30 PSI), so
please stop turning the regulator knob when the
pressure is enough to tap beer out with perfect foam.
Too much pressure would cause over foam. When the
beer stopped or ow slower, try turning the regulator
knob on slowly, to get bigger pressure.
6. When you nish tapping, please turn regulator knob to
OFF position.
7. If there is no beer owing out, then the CO2 capsule
needs to be replaced, unless no beer is remained
(Normally, 16g capsule can tap 4-5 liters of beer).
Caution: Removing a punctured capsule from regulator
should be done slowly. Swish is expected if pressure
remains.
8. Turn the regulator knob o and install a new capsule
into the regulator by following above steps.
TROUBLE SHOOTING GUIDE
1. Faucet Leakage
Solution: Screw out and remove the faucet, then install
again, make sure the faucet can match the connection
of spear tightly.
2. Too much Foam
Solution: Decrease the pressure properly.
3. Leakage of CO2
CO2 capsule should be installed properly and tightly.
In case there is CO2 leakage, please observe the position
of leakage and continue with the tightening process, but
never screw out if gas remains.
PART FOUR:
WARNING
1. Keep away from children under 18.
2. Never point cylinder towards someone's face.
3. Do not heat over140°F as rupture may occur!
4. Discontinue using of this equipment if unsolvable
leakage or visible damage is found.
5. Capsule end become punctured when turned into
regulator base. Unscrewing before it's empty can result
in loss of high pressure gas. Please remember, never
unscrew the CO2 capsule before gas used up, liquid CO2
spray onto unprotected skin may cause freezing burns.
6. Exterior of capsule may become frozen when in use,
this is normal. But don't touch with bare hands, your
ngers could stick to the frozen surface and cause
frostbite.
7. Please ship via land or sea shipment, never bring CO2
capsule when you travel by air.
O RING INFORMATION:
E
D
C
B
A 35x3.1 MM (1pcs)
B 13x10x2 MM (1pcs)
C 8x1.5 MM. (1pcs)
D 11x1.5 MM (2pcs)
E
8x2.5 MM (3pcs)
(Out Diamter* Thickness)
O RING ASSEMBLY:
Questions? Issues?
Phone: (1) 718-535-1800
Email: support@pyleusa.com
This product can expose you to a chemical or group of checmicals, which
may include "Chromium" which is known in the state of California to cause
cancer, birth defects, or other reproductive harm. For more info, go to
https://www.p65warnings.ca.gov/.
www.NutriChefKitchen.com
A
We are here to help!

Advertisement

loading

This manual is also suitable for:

Pkbrtp299