Screed Drying - Viessmann B1HF Installation And Service Instructions Manual

Table of Contents

Advertisement

Appliance functions
90
3.5
A
+20
Outside temperature in °C
Fig. 54
Changing the slope
A
Changing the level (vertical parallel offset of the
B
heating curve)

Screed drying

When enabling screed drying, observe the information
provided by the screed manufacturer.
When the screed drying function is activated, the heat-
ing circuit pumps of all heating circuits are switched on
and the flow temperature is maintained in accordance
with the selected profile. After completion (30 days),
the heating circuits with mixer are automatically con-
trolled with the set parameters.
Screed drying is adjusted in the system configuration:
0 = OFF
2 = Temperature profile A
3 = Temperature profile B
...
7 = Temperature profile F
Note
During screed drying, DHW heating is not available.
Parameter "Screed drying":
Temperature profile A (EN 1264-4)
50
40
30
20
10
1
5
10
Fig. 55
(cont.)
1.4
B
0.2
-20
15
20
25
30
Days
Observe EN 1264. The report to be provided by the
heating contractor must contain the following details
regarding heat-up:
Heat-up data with the relevant set flow temperatures
Max. flow temperature achieved.
Operating state and outside temperature at handover
Note
Temperature profile 6 ends after 21 days.
The function continues after a power failure or after the
control unit has been switched off. When screed drying
has completed or been manually switched off, the sys-
tem is controlled in accordance with the selected
parameters.
Function description