Wiring
Warning: Make sure main power is turned off before making
wiring.
Make wire connections as indicated. Connect Black and Blue
wire from fan to Black (Hot) wire from house. Connect White
wire from Fan to White (Neutral) wire from house. Connect all
green grounded wires from fan to Grounded wire from
House. Make sure that no filaments are outside of the wire
connectors. (Fig. 7)
For control of fan and light separately from wall location,
follow diagram as shown. (Fig. 7-1)
Note: A professional electrician is recommended for this
type of installation.
Note: Wrap each wire connector separately with electrical
tape as an extra safety measure.
Canopy Installation
Partially loosen 2 of the set screws on mounting bracket
corresponding to the slotted holes on the canopy upper ring.
Remove the other 2 set screws. Save screws.
Raise canopy to mounting bracket, aligning loosened screws
in mounting bracket with slotted holes in canopy. Twist
canopy to lock. Reinstall screws (with washers) that were
previously removed and then tighten all screw securely. (Fig.
8, Fig. 8-1)
© 2013 Monte Carlo Fan Company
Wiring Option with Wall Controller
Mounting bracket
Mounting bracket
Flush mount
6
Wall Switch
White
Black
Grounded/
Green
Black
Blue
White
Power supply
Set screws
Canopy
Downrod mount
Fig. 8
Set screws
Canopy
Fig. 8-1
Power
Line
Fig. 7
Fig. 7-1