Page 2
Training with the E720 Congratulations on your purchase of E720. FIRST DEGREE FITNESS is proud to present the Rower as a home use product featuring patented Adjustable Fluid Resistance. As with any piece of fitness equipment, consult a physician before beginning your E720 exercise program.
Safety Safety Information • Before using this product, it is essential to read this ENTIRE operation manual and ALL instructions. The Rower is intended for use solely in the manner described in this manual. • UNDERSTANDING EACH AND EVERY WARNING TO THE FULLEST IS IMPORTANT •...
Page 5
Inspection • DO NOT use or permit use of any equipment that is damaged and/or has worn or broken parts. For all FIRST DEGREE FITNESS equipment use only replacement parts supplied by FIRST DEGREE FITNESS. • EQUIPMENT MAINTENANCE - Preventative maintenance is the key to smooth operating equipment as well as to keep your liability to a minimum.
Assembly Instructions STEP 1 Assembly Seat Back and Lower Seat REQUIRED Seat Back[4] to Upper Seat Frame[3] using Upper Seat Frame [3] 4x M6x20mm Bolts[9] and 4x M6 Washers[11] Seat Back [4] b) Lower Seat[5] to Upper Seat Frame[3] using Lower Seat [5] 4x M6x20mm Bolts[9] and 4x M6 Washers[11] 8 x M6 x 20mm Blots [9]...
Page 10
Assembly Instructions STEP 5 Tank Filling and Water Treatment REQUIRED Filling requires a large bucket (not Supplied) and the supplied water Funnel and Hose [22]. Filling will take Funnel and Hose [22] approximately 8 liters of water. Open the yellow fill plug on the back of the tank and insert hose (rotating the impeller slightly may be necessary to allow the hose to pass).
Operation Instructions E720 Control Arm Chain Tensioning Bolts: Allows for tightening the chain or adjustment from side to side. Make sure when tightening only to adjust the same amount for both bolts, otherwise the sprocket will be misaligned. Note: Tightening the right bolt only will pull the right side of the crank assembly toward you, tightening the left will pull the left side toward you.
Note: For complete operational instructions, please refer to the computer manual, which is included with your Rower. Using the FIRST DEGREE FITNESS USB Interface Description: The USB connectivity now built in to all new models of FDF Console and IPM allow you to enhance your exercise experience by connecting to your home PC or Laptop.
First degree fitness is not responsible for performing regular inspection and maintenance actions for your machines. Instruct all personnel in equipment inspection and maintenance actions and also in accident reporting and recording. First degree fitness representatives are available to answer any questions that you may have. Item...
Troubleshooting Fault Probable Cause Solution Water changes color Rower is in direct Change rower location to reduce sunlight or has not direct exposure to sunlight. Add water or becomes cloudy. had water treatment or change tank water as directed in the water treatment section treatment.
Tank Belt Adjustment 2. Using a long tool, push out the rear 1. Remove large metal inspection plate. end cap as pictured below left. This will give you access to the tank tensioning bolt (shown lower right). End Cap 3. Loosen both the rear and front tank 4.
Metal Frame – 10 Year Limited Warranty First Degree Fitness will repair or replace the metal Main Frame should it fail due to any defect in materials or workmanship within 10 years of the original purchase. Warranty does not apply to frame coating.
Page 17
NOUS CONTACTER Pour le soutien à la clientèle, veuillez visiter firstdegreefitness.com/support TAÏWAN T: +886 3 478 3306 764 Chung Shan South Rd Yangmei Taoyuan Taiwan R.O.C.