Mitsubishi Electric MJ-E15BX-S1-IT Service Manual page 33

Hide thumbs Also See for MJ-E15BX-S1-IT:
Table of Contents

Advertisement

6. Removing the drain pan assembly
Step 1) Remove the water tank, the front case, the rear
case, the left and right cases, and the blower fan
assembly following the steps in sections 1 to 5
above.
2) Remove the drain EVA setscrews (2).
3) Detach the catches (right, left, and center: 1
point each) on the drain pan and the drain EVA,
and remove the drain EVA while lifting the heat
exchanger from the main unit.
4) Detach the catches (4 points) in the drain pan
from the base, and remove the drain pan while
lifting the heat exchanger from the main unit.
Repairable
Compressor
parts
<Compressor wiring diagram>
Gray (C)
Gray (R)
(See Pic. 1)
Gray (R)
Red (S)
Pic. 1
Drain EVA
Setscrew
Heat exchanger
Catch
Drain EVA
Setscrew
Drain pan
Base
33