2. Low Operation
① Control Summary
(a) Dehumidifying operates continuously regardless of the humidity.
(b) The constant compressor, cool air and warm air fans operate continuously.
(c) By reducing the rank of the blower fan compared to high operation, the dehumidifi cation function is decreased
during operation.(Creating low noise)
Target part
Operation
② Low operation is disabled in the following cases.
(a) When the LAUNDRY switch is pressed, it switches to the previously set LAUNDRY operation mode (HIGH, NORMAL or HEAVY).
(b) When the DEHUMIDIFYING switch is pressed, it switches to DEHUMIDIFYING HIGH operation.
(c) When the SPOT AIR switch is pressed, it switches to the previously set SPOT AIR operation mode (COOL
AIR/LOW, COOL AIR/VARY or WARM AIR).
(d) When the DEO-DRY switch is pressed, it switches to the DEO-DRY mode operation.
3. High Operation
① Control Summary
(a) Dehumidifying operates continuously regardless of the humidity.
(b) The constant compressor, cool air and warm air fans operate continuously.
(c) By increasing the rank of the blower fan compared to low operation, the dehumidifi cation function is increased during operation.
Target part
Operation
② High operation is disabled in the following cases.
(a) When the LAUNDRY switch is pressed, it switches to the previously set LAUNDRY operation mode (HIGH, NORMAL or HEAVY).
(b) When the DEHUMIDIFYING switch is pressed, it switches to dehumidifying auto operation.
(c) When the SPOT AIR switch is pressed, it switches to the previously set SPOT AIR operation mode (COOL
AIR/LOW, COOL AIR/VARY or WARM AIR).
(d) When the DEO-DRY switch is pressed, it switches to the DEO-DRY mode operation.
SPOT AIR
1. Condensation prevention operation
① Control Summary
(a) Dehumidifying operates continuously regardless of the humidity.
(b) The constant compressor, cool air and warm air fans operate continuously.
(c) Perform warm air operation by placing the damper position in warm air mode.
Target part
Operation
② Condensation prevention operation is disabled in the following cases.
(a) When the LAUNDRY switch is pressed, it switches to the previously set LAUNDRY operation mode (HIGH, NORMAL or HEAVY).
(b) When the DEHUMIDIFYING switch is pressed, it switches to the previously set DEHUMIDIFYING operation
mode (DEHUMIDIFYING LOW, DEHUMIDIFYING HIGH or AUTO).
(c) When the SPOT AIR switch is pressed, it switches to COOL AIR/LOW operation.
(d) When the DEO-DRY switch is pressed, it switches to the DEO-DRY mode operation.
2. COOL AIR/LOW Operation
① Control Summary
(a) Dehumidifying operates continuously regardless of the humidity.
(b) The constant compressor, cool air and warm air fans operate continuously.
(c) Perform cool air operation by placing the damper position in cool air mode.
Target part
Operation
② COOL AIR/LOW operation is disabled in the following cases.
(a) When the LAUNDRY switch is pressed, it switches to the previously set LAUNDRY operation mode (HIGH, NORMAL or HEAVY).
(b) When the DEHUMIDIFYING switch is pressed, it switches to the previously set DEHUMIDIFYING operation
mode (DEHUMIDIFYING LOW, DEHUMIDIFYING HIGH or AUTO).
(c) When the SPOT AIR switch is pressed, it switches to COOL AIR/VARY operation.
(d) When the DEO-DRY switch is pressed, it switches to the DEO-DRY mode operation.
10
Compressor
Cool air fan
ON
Rank control
Compressor
Cool air fan
ON
Rank control
Compressor
Cool air fan
ON
Rank control
Compressor
Cool air fan
ON
Rank control
Warm air fan
Solenoid valve
Rank control
OFF
Warm air fan
Solenoid valve
Rank control
OFF
Warm air fan
Solenoid valve
Rank control
OFF
Warm air fan
Solenoid valve
Rank control
OFF
Louvre
Damper
Operation mode
Dehumidifying position
Louvre
Damper
Operation mode
Dehumidifying position
Louvre
Damper
Operation mode
Warm Air Position
Louvre
Damper
Operation mode
Cool Air Position