7-2-5 Function TEST
1. This is a compulsory operation for TEST, SVC, cleaning, etc. It is operated by pressing the water supply control KEY for 3 seconds.
2. It operates in the Ice Making mode, but not in the Ice-Removing mode or water supply process. (If there is an ERROR, it
can only be checked in the TEST mode.)
3. If the water supply control KEY is pressed for 3 seconds in the Ice-Making mode (no matter what condition the Ice-
Making tray is in) the Ice-Removing operation starts immediately. Water is not yet frozen, so water is poured instead of
ice. If the control doesn't operate normally in the TEST mode, check and repair as needed.
4. After water is supplied, the normal CYCLE is followed: ice making
5. When Stage 5 is completed in the TEST mode, minimize MICOM in 5 seconds, the time needed to supply water resets to
the previous status in the TEST mode.
<Diagnosis TABLE>
STAGE
1
2
3
4
5
(detection of full-
6
7-3 DEFECT DIAGNOSIS FUNCTION
7-3-1 ERROR CODES shown on Ice Maker water supply control panel
NO
DIVISION
1
Normal
Ice-Making
2
Sensor
malfunction
Ice Maker Kit
3
malfunction
ERROR indicators in table can be checked only in TEST mode.
ITEMS
HEATER
MOTOR
HALL IC I
(detection of
position)
VALVE
HALL IC II
filled Ice)
Mark Previous Status on
Reset
TEST MODE
INDICATOR
Mark time to
supply
→ Harvest → Fill → Park Position.
INDICATOR
Five seconds after heater starts, heater will
go off if temperature recorded by sensor is
50°F(10°C) or lever is in up position.
Five seconds after heater starts, you can
confirm that motor is moving.
You can confirm Hall Ic detection of position.
Two seconds after detection of initial
position, you can confirm that valve is on.
You can check whether hall is sensing Full
ice condition. (If there is a full-filled error, the
fifth LED is not on.)
Five seconds after fifth stage is completed,
the icemaker reset at initial status.
CONTENTS
None
Open or short-circuited wire
When ejector blades don't reach
park position over 18 minutes
since Harvest Mode starts.
- 21 -
REMARKS
REMARKS
Display switch
operates properly
Make sure that the wire
on each sensor is
connected.
Check of
HALL IC/MOTOR/
HEATER/RELAY

Hide quick links: