6-5-1 SEALED SYSTEM DIAGNOSIS
"Not Cooling" Complaint
All components operating, No airflow problems, Not frosted up as a defrost problem
problem has been isolated to sealed system area
Frost
None
Partial
Pattern?
Equalization
Equalization
Test
Test
Very Fast
Very Slow
Very Slow
Very Fast
Fast
Inefficient
Partial
Complete
Compressor
Restriction
Restriction
Condenser
Cap Tube
Temperature
Sound
Hotter than Normal
Faint
Room Temperature
None to Weak
Air/Low Side
Loss of Change
Leak
Compressor Not
Pumping
Trace of Oil
Yes
No
Leak
Undercharge
(The equalization test is trying to restart a compressor using a start kit after it has been operating.)