ELECTRICAL INSTALLATION

The manufacturer is not responsible if
you do not follow the safety
precautions from the Safety chapters.
This appliance is supplied without a main plug and
a main cable.
CABLE
Cable types applicable for installation or
replacement:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F, H05
V2V2-F (T90), H05 BB-F
For the section of the cable refer to the total power
on the rating plate.

CONNECTING THE TERMINAL BOARD

The appliance has a six-pole terminal board. The
jumpers (bridges) are set for operation on a 400 V
three-phase with a neutral wire.
1

ENERGY EFFICIENCY

PRODUCT FICHE AND INFORMATION ACCORDING TO EU 65-66/2014
Supplier's name
Model identification
Energy Efficiency Index
Energy efficiency class
Energy consumption with a standard load, conventional
mode
Energy consumption with a standard load, fan-forced mode
Number of cavities
Heat source
Volume
Type of oven
1 = 45 mm
2 = 45 mm
3 = 60 mm
4 = 60 mm
= 70 mm
2
3
4
L 1 – 2 – 3 = phase cables
N 4 = neutral cable
= earth cable
If the mains voltage is different, rearrange the
jumpers on the terminal board (refer to the
connection diagram below). Connect the ground
cable to the terminal. After you connect the supply
cable to the terminal board, attach it with a junction
clamp.
3N ~
1
2
3
5
4
Zanussi
ZOU30601XU
100.0
A
0.93 kWh/cycle
0.85 kWh/cycle
1
Electricity
72 l
Built-Under Oven
2N ~
230V ~
1
2
3
1
2
3
5
4
5
4