Page 1
BATTERY CHARGER Smart Battery Charger Smart Battery Charger Smart Battery Charger Model No. WSC-1250 WSC-2425 Manual Please read this manual carefully before installing and starting up this device.
Contents 1 General safety and Installation instructions 1.1 Operate the device safely 1.2 Safety instructions when installing the device 1.3 Electrical cables 1.4 Installation on boats 2 WARNING 3 Applications and Descriptions 4 Introduction of the unit variants 5 Accessories 5.1 Temperature Sensor TF-100 5.2 Remote Controller RC-600 5.3 Remote Controller RC-601D...
General safety and Installation instructions 1.1 Operate the device safely Warning! Failure to observe this instruction can cause material damage, device malfunction, or danger of bodily injuries. Fundamental safety measures should be observed when using electrical equipment to avoid the danger of: –...
WARNING Warning! Please read carefully about the following precautions. Damages caused by failure to follow the instructions below will NOT be covered by warranty. • Use the charger only as intended. • Do NOT operate the charger if the housing or the cables are damaged. •...
Front view Model-No.: WSC-1250 and WSC-2425 (See Figure 1 WSC-1250 / 2425 / Charger Front View, Page. 2) No. Description 1. "TEMP" connection for temperature sensor (accessory TF-100) 2.
Accessories 5.1.2 Installation • Lay the cables from the batteries to the charger. • Connect the temperature sensor to the "TEMP" socket of the charger. • Connect the temperature sensor to the negative pole of the battery, or use a double-sided adhesive tape to attach the sensor to the top of the battery or in the vicinity of the battery (see Figure 15 Temperature Sensor Setup, Page.
Accessories 5.3 Remote Controller RC-601D The remote controller RC-601D, Figure 12 Remote Controller RC-601D, Page. 7) displays real-time information, settings and count down for different charging stages. 5.3.1 Functions • Switch the charger ON and OFF. • Half power mode ON / OFF. •...
Mounting of Battery Charger For mounting battery charger on wall or flat places please refer from Figure 3 WSC-1250 / WSC-2425 Charger Top View (Page 3) regarding the size of housing and the location of mounting holes for your installation.
(see Figure 8 Switch, Page. 5). Warning! Please follow the table below to ensure correct operation of the charger Settings for the charging voltage for WSC-1250 and WSC-2425: Table 8-1 Switch Configure Charging Voltage Switch 1...
Settings 8.2 Half power mode setting When the switch S2 “HALF POWER” is pushed, the output power will reduce to half of the chargers' amp rating and the “STATUS” LED will flash. The switch S2 is a kind of no memory switch.
Settings Table 8 -5 VOID Setting table for pushing switch on front panel Push switch on front Original working mode panel Half power Equalization Others Power Supply Exit "HALF Enter "HALF S2 "HALF POWER" POWER" VOID POWER" VOID pushed ("STATUS" LED ("STATUS"...
Page 20
Using the Charger 9.1.1 I phase (bulk) The "STATUS" LED constantly lights Red. In the first stage of the charging process, the depleted battery is charged with a constant current until the battery voltage reaches I phase setting voltage (13.5V/27.0V or 13.8V/27.6V).
Using the Charger 9.1.5 Equalization The function of equalization could be activated as long as the battery charger is NOT in the half power mode or power supply mode. The function of equalization will be activated only when the battery is charged and stays in Uo phase with <...
Using the Charger Note • The power switch at the unit must be switched ON, so that the unit can be switched ON and OFF with the remote control. • The "ON/OFF" button on the RC-600 should be pressed for 2 seconds to switch OFF the battery charger, and 0.5 second to turn ON.
The temperature sensor is only working in I, Uo and U phases. • The output voltage is adjusted according to the function -25mV/°C for WSC-1250 and -50mV/°C for WSC-2425. However, the maximum output voltage is 15V/30V, and the minimum is 13.2V/26.4V.
Using the Charger Figure 22 Fan Speed 9.5 Functional check The status LED in the front of the unit can be used to check the status of the charging process. Note The optional remote controller can also be used to check the status of the charging process. The LEDs on the remote controller indicate different charging phases with their colors respectively.
Trouble Shootings 10.1 The battery voltage would NOT increase after charging • If possible, measure with a suitable multi-meter during the charging to verify if the voltage at the battery terminals increases. • Determine whether the terminals are connected properly to the battery poles. Clean the battery poles if necessary to ensure better connection.
Trouble Shootings 10.4 Please refer to the following table for other trouble shootings Table 10-1 Abnormal Functional Check Table "E.Q." LED "STATUS" LED Status Red, flashing Red, constantly lit Short circuit and low voltage, shut down Red, flashing Orange, constantly lit Battery temperature abnormal, stop charging (TF-100) Red, flashing...
Specifications Model Number: WSC-1250 WSC-2425 Input voltage range 100-240V AC Input frequency 50-60Hz Power factor correction >0.97 Efficiency at 230V AC >91% >93% Efficiency at 115V AC >89% >91% Input Current at 230V AC 3.62A 3.51A Input Current at 115V AC 7.32A...
Declaration of Conformity For the following equipment : Product Name: SMART BATTERY CHARGER Model No.: WSC-1250 and WSC-2425 Trade Name: Applicant: SAMLEX EUROPE B. V. Address: ARIS VAN BROEKWEG 15, 1507 BA ZAANDAM THE NETHERLANDS Is herewith confirmed to comply with the EMC requirements set out in the Directive 2014/30/EU and...
Need help?
Do you have a question about the WSC-1250 and is the answer not in the manual?
Questions and answers