Siemens RUGGEDCOM i801 Installation Manual page 36

Hide thumbs Also See for RUGGEDCOM i801:
Table of Contents

Advertisement

Chapter 6
Certification
IEEE 1613 EMC Immunity Type Tests
ESD
Radiated RFI
Fast Transient
Oscillatory
Environmental Type Tests
Test
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60068-2-6
IEC 60068-2-27
28
Description
Enclosure Contact
Enclosure Air
Enclosure ports
Signal ports
DC Power ports
Earth ground ports
Signal ports
DC Power ports
Cold Temperature
Dry Heat
Humidity (Damp Heat, Cyclic)
Vibration
Shock
2.5 kV common mode @ 1MHz
2.5 kV common, 1 kV differential mode @ 1MHz
Description
Test Ad
Test Bd
Test Db
RUGGEDCOM i801
Installation Guide
Test Levels
± 8 kV
± 8 kV
35 V/m
± 4 kV @ 5 kHz
± 4 kV @ 5 kHz
± 4 kV @ 5 kHz
Test Levels
-40 °C (-40 °F), 16 Hours
85 °C (185 °F), 16 Hours
95% (non-condensing),
55 °C (131 °F), 6 cycles
1 g @ 10-500 Hz
30 g @ 11 ms
EMC and Environmental Type Tests