Downloading from the Meter

Data collected in the SML-200 may be downloaded to a PC so that it can be saved for future
use. It can also be viewed as a list or in a graph. All downloading is performed through the
Logger dialog box. On the Panel dialog box, click MEMORY to access the Logger functions. To
save the data, see Using Lists. Refer to the illustration in the Internal Logging section.

Viewing Data from the Meter

1.
Click NUMBERS OF SETS. The number of sets appears in the text box.
2.
Click TIME OF RECORDING. A list of the sets and their date and time appear.
3.
Click anywhere in the row of a set to select it. The number of recordings in that set
appears in the NUMBERS OF REC text box.
4.
Click SHOW DATA. The REC_LIST dialog box appears.
5.
From the REC_LIST dialog box, save the file, print it in a tab-delimited format, or view it in
a graph. See Using Graphs or Using Lists.

Clearing the Memory

After saving the files that you need, you can clear the memory in two ways. The first method is
to use the RESET button on the meter as described in the Using the Features section. The
second method is from Sound Meter. On the SML-200 image in the Panel dialog box, click
RESET. "dEL" flashes on the meter's display, and the emulation display on the PC briefly
shows no sound level and indicates that there is "NO COM."