560XL Series Optical Power Meters*
Detector size and
composition
Calibrated wavelengths
Measurement range
Linearity:
+3 to -3 dBm
-3 to -50 dBm
-50 to -60 dBm
Absolute accuracy
Wavelength dependence (typical):
820 to 880 nm
975 to 985 nm
1270 to 1330 nm
1500 to 1625 nm
Polarization dependence
Resolution
Optical connector interface
Functions
Power requirements
Battery life
Environment
Operating temperature
Storage temperature
Humidity, non-condensing 0% to 95%
Dimensions
Weight
* Within specified operating environment of 20 °C to 25 °C.
10
1 mm InGaAs
850, 1300, 1310, 1550 nm
+3 to -60 dBm
±0.5 dB
±0.05 dB
±0.5 dB
±0.25 dB
2.00 dB
0.25 dB
0.30 dB
0.30 dB
< 0.1 dB
±0.01dB
FC, SC, or ST
dB: Relative units
dBm: Absolute units
λ: Select wavelength
CAL: Calibrate unit
Two AA-size alkaline batteries
> 100 hours
-15 °C to 55 °C
-35 °C to 70 °C
7.2 x 14.2 x 3.5 cm
(2.8 x 5.6 x 1.4 in)
250 g (8.9 oz)