Chauvet Arena HAZER 2 User Manual
Chauvet Arena HAZER 2 User Manual

Chauvet Arena HAZER 2 User Manual

Chauvet water system user manual

Advertisement

Snapshot
Use on Dimmer
Outdoor
Sound Activated
DMX
Master/Slave
115 V / 230 V Switch
Resettable Breaker
User Serviceable
Duty Cycle
User Manual
th
3000 N 29
Ct, Hollywood, FL 33020 U.S.A.
(800) 762-1084 – (954) 929-1115
FAX (954) 929-5560
www.chauvetlighting.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Arena HAZER 2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Chauvet Arena HAZER 2

  • Page 1 Snapshot Use on Dimmer Outdoor Sound Activated Master/Slave 115 V / 230 V Switch Resettable Breaker User Serviceable Duty Cycle User Manual 3000 N 29 Ct, Hollywood, FL 33020 U.S.A. (800) 762-1084 – (954) 929-1115 FAX (954) 929-5560 www.chauvetlighting.com...
  • Page 2: Table Of Contents

    ABLE OF ONTENTS 1. BEFORE YOU BEGIN ... 3 ... 3 HAT IS INCLUDED ... 3 NPACKING NSTRUCTIONS ... 3 ANUAL ONVENTIONS ... 3 CONS ... 4 AFETY NSTRUCTIONS 2. INTRODUCTION ... 5 ... 5 EATURES DMX C ... 5 HANNEL UMMARY ...
  • Page 3: Before You Begin

    Manual Conventions CHAUVET manuals use the following conventions to differentiate certain types of information from the regular text. ONVENTION...
  • Page 4: Safety Instructions

    Safety Instructions Please read these instructions carefully. It includes important information about the installation, usage and maintenance of this product. Please keep this User Manual for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet. Always make sure that you are connecting to the proper voltage, and that the line voltage you are connecting to is not higher than that stated on the decal or rear panel of the fixture.
  • Page 5: Introduction

    2. I NTRODUCTION Features 2-channel DMX professional hazer Adjustable haze output via wired remote or DMX Adjustable blower speed via wired remote or DMX A d d i t i o n a l F e a t u r e s Adjustable blower angle 3-pin and 5-pin DMX connections Wired remote with LCD screen...
  • Page 6: Product Overview

    Product Overview Power switch Power Breaker Wired remote with LCD backlit control panel 3-pin DMX in/out 5-pin DMX in/out LED-illuminated tank Door latch Arena Hazer™ 2 User Manual Carrying handle Blower 4/20/2010 4:23 PM...
  • Page 7: Product Dimensions

    Product Dimensions Arena Hazer™ 2 User Manual 4/20/2010 4:23 PM...
  • Page 8: Setup

    Unplug the product from the power outlet. Allow to cool for 5~15 min. Press on the breaker button until it remains in place. In the event that this breaker will not reset, contact CHAUVET for troubleshooting. The fixture may need to be serviced. LED-Illuminated Tank The fluid tank on this hazer is equipped with LEDs, in order to provide visual fluid level indication, as well as to provide the readiness of the hazer.
  • Page 9: Operating Instructions

    4. O PERATING Configuring the Starting Address Each fixture requires a starting address from 1~512. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the starting address. For example, a fixture that uses seven DMX channels and is addressed to start on DMX channel 100, will read data from channels: 100, 101, 102, 103, 104, 105 and 106.
  • Page 10: Control Panel Functions (Cont.)

    Control Panel Functions (cont.) This operating mode will allow you to control the Arena Hazer™ 2 with an external DMX controller. You must set the starting address for this mode. If this is your first time using DMX, then it is recommended that you refer to the “DMX Primer”...
  • Page 11: Led Indicators

    LED Indicators When the fluid is low in the hazer, the low fluid indicator (shown as NO FLUID on the hazer) will light solid. When the hazer detects DMX signal, the DMX indicator (shown as DMX OK on the hazer) will light solid. Auto Cut-Off Feature This product has a safety feature to keep the machine from becoming damaged.
  • Page 12: General Troubleshooting

    Long cable / Low level signal Loss of signal Too many fixtures Interference from AC wires If you still have a problem after trying the above solutions, please contact CHAUVET® Technical Support. Contact Us W o r l d W i d e...
  • Page 13: Appendix

    5. A PPENDIX DMX Primer There are 512 channels in a DMX connection. Channels may be assigned in any manner. A fixture capable of receiving DMX will require one or a number of sequential channels. The user must assign a starting address on the fixture that indicates the first channel reserved in the controller. There are many different types of DMX controllable fixtures and they all may vary in the total number of channels required.
  • Page 14: Warning

    Warning! All haze machines are prone to clogging due to the thick consistency of the fog liquid and the high temperature at which it vaporizes. However, a properly maintained fog machine should provide years of reliable use. Cleaning your fog machine regularly will help reduce costly replacement and repair charges.
  • Page 15: Fixture Linking

    Maximum recommended number of fixtures on a serial data link: 32 Data Cabling To link fixtures together you must obtain data cables. You can purchase CHAUVET-certified DMX cables directly from a dealer/distributor or construct your own cable. If you choose to create your own cable please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic interference.
  • Page 16: 3-Pin To 5-Pin Conversion Chart

    3-Pin to 5-Pin Conversion Chart If you use a controller with a 5-pin DMX output connector, you will need to use a 5-pin to 3-pin adapter. The chart below details a proper cable conversion: Conductor Ground/Shield Data ( - ) signal Data ( + ) signal Not used Not used...
  • Page 17: Returns Procedure

    Package must be clearly labeled with a Return Merchandize Authorization Number (RMA #). Products returned without the RMA # will be refused. Call CHAUVET and request an RMA # prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return.
  • Page 18: Technical Specifications

    Technical Specifications WEIGHT & DIMENSIONS Length ... 18.1 in (462 mm) Width... 12.7 in (322 mm) Height ... 11.8 in (303 mm) Weight... 37.7 lbs (17.1 kg) POWER AC power ... 115 VAC, 60 Hz or 230 VAC, 50 Hz Breaker ...