Propane Supply; Ventilation; Specifications - Desa TC275 Owner's Manual

Propane construction heater
Hide thumbs Also See for TC275:
Table of Contents

Advertisement

PROPANE
SUPPLY

VENTILATION

SPECIFICATIONS

099156
You must provide propane gas and propane tank(s).
Use this heater only with a propane vapor withdrawal supply system. See
Chapter 5 of the Standard for Storage and Handling of Liquified Petroleum Gas,
ANSI/NFPA 58. Your local library or fire department will have this booklet.
The amount of propane gas ready for use from propane tanks varies. Two factors
decide this amount.
1. The amount of liquid propane gas in tank(s)
2. The temperature of tank(s)
The chart below shows the minimum number of 100-pound tanks needed to run
the heater. Connect tanks together with a manifold. Do not operate this product
with any tank smaller than 100 pounds.
Average Temperature (
At Tank Location
Number Of Tanks
Less gas is vaporized at lower temperatures. Two or more 100-pound tanks or one
larger tank may be needed in colder weather. Your local propane gas dealer will
help you select the proper supply system.
Follow the minimum fresh outside air ventilation requirements.
If proper fresh outside air ventilation is not provided, carbon
monoxide poisoning can occur. Provide proper fresh outside
air ventilation before running heater.
FRESH OUTSIDE AIR OPENING REQUIREMENTS
HEATER SIZE
275,000 BTU/Hr
230,000 BTU/Hr
Rating(BTU/Hr)
Fuel
Fuel Consumption
Gallons/Hour
Pounds/Hour
Supply Pressure (To Regulator)
Maximum
Minimum, for input adjustment
Regulator Outlet Pressure
Weight (Pounds)
Shipping Weight (Pounds)
Size - L x W x H (Inches)
°
F)
60°
40°
32°
2
2
3
!
WARNING
SQUARE FEET OPENING
8.2
6.9
TC275
230,000
Propane Vapor Only
2.5
10.7
Tank Pressure
40 psi
10 psi
15
19
1
1
18
/
x 16 x 23
/
2
20°
10°
3
3
3
RCP275
275,000
Propane Vapor Only
3
12.75
Tank Pressure
40 psi
14 psi
15
19
1
1
18
/
x 16 x 23
8
2
/
8
5