PRODUCT IDENTIFICATION

Top
Shell
Ignitor
Electrode
Thermocouple
Piezo
Ignitor
Button
Hose/
Regulator
Assembly
Figure 1 - Product Identification

UNPACKING

1. Remove all packing items applied to heater for shipment. Keep
plastic cover caps (attached to valve inlet and hose/regulator
assembly) for storage.
2.
Remove all items from carton.
3.
Check all items for shipping damage. If heater is damaged,
promptly inform dealer where you bought heater.

THEORY OF OPERATION

The hose/regulator assembly attaches to the
The Fuel System:
propane gas supply. This provides fuel to the heater.
The piezo ignitor lights the burner fuel
The Ignition System:
supply.
The Automatic Control System:
shut down if the flame goes out.
104782-01D
Base
Control Knob
Valve
Inlet
This system causes the heater to
For more information, visit www.desatech.com
For more information, visit www.desatech.co
PRODUCT IDENTIFICATION
THEORY OF OPERATION

PROPANE SUPPLY

Propane gas and propane tank(s) are to be furnished by the user.
Use this heater only with a propane vapor withdrawal supply
system. See Chapter 5 of the Standard for Storage and Handling of
Liquefied Petroleum Gas, ANSI/NFPA 58 and/or CAN/CGA B149.2.
Your local library or fire department will have this booklet.
The amount of propane gas ready for use from propane tanks varies.
Two factors decide this amount.
1.
The amount of liquid propane gas in tank(s)
2.
The temperature of tank(s)
The chart below shows the minimum number of 45 kg (100 lb) tanks
needed to run the heater. Connect tanks together with a manifold. Do
not operate this product with any tank smaller than 45 kg (100 lb).
Average Temperature
°C (°F) At Tank Location
16° (60°)
4° (40°)
0° (32°)
-6.7° (20°)
-12° (10°)
-18° (0°)
Less gas is vaporized at lower temperatures. You may need two or
more 45 kg (100 lb.) tanks or one larger tank in colder weather. Your
local propane gas dealer will help you select the proper supply
system. The minimum surrounding air temperature rating for each
heater is -29°C (-20°F).

VENTILATION

WARNING: Provide at least a .56 m
of fresh, outside air while running heater. If proper
fresh, outside air ventilation is not provided, carbon
monoxide poisoning can occur. Provide proper fresh,
outside air ventilation before running heater.
FRESH OUTSIDE AIR OPENING REQUIREMENTS:
HEATER SIZE - 200,000 Btu/Hr OPENING - .56 m
UNPACKING
PROPANE SUPPLY
VENTILATION
Number Of Tanks
45 kg (100 lb)
2
2
2
2
3
3
2
2
(6 ft
) opening
2
(6.0 ft
3
2
)