Setup Function Procedures; Setup Mode; Status Code Scrolling; Handset Plug Connections & Outline Drawing - GE IC3645SR4T405E1 Installation And Operation Manual

Separately excited transistorized traction control
Table of Contents

Advertisement

ADJUSTABLE FEATURES
IT TRANSISTOR CONTROLS
Section 5.3 Set-up Function Procedures
With the Handset connected, hold down the CONT key
and turn on the key switch. This will place you in the set-
up mode, ready to monitor or adjust control function
settings.
NOTE: The term "Push" means to depress key for
approximately one second.
Section 5.3.1 Setup Mode
SET-UP MODE
DISPLAY
ACTION
SHOWS
Hold Down CONT
8 8 8 8
And Turn On Key
U 0 0 5
Push Function Number
After One Second
0 8 5
Time Delay
0 8 5
Push CONT
Change Value With
125
Adjustment Knob
125
Push STORE
8 8 8 8
Push ESC
At this point, another function can be monitored/changed
by pushing another function number, or the vehicle can be
placed in the run mode by holding the ESC key down for
one second or longer. The display will return to either the
diagnostics mode, the BDI display, or a blank display (if
BDI is not used and there are no fault codes). The
vehicle can now be operated with the Handset connected,
or the Handset can be disconnected before operation.
NOTE: You can return to the segment check mode at
any time, by holding down the ESC key until 8888
appears in the display.
Section 5.3.2 Status Code Scrolling
The SX and IT families of controllers furnish a function
register that contains the last 16 "stored status codes"
that shut down vehicle operation (a PMT type fault that is
reset by cycling the key switch) and the battery state of
charge reading at the time the fault occurred. The first of
REMARKS
Segment Check
Displayed
Selected Function No.
Is Displayed
Stored Value For The
Function Is Displayed
Display Value
Will Blink
Value Changes
While Blinking
New Value Stored And
Blinking Stops
Segment Check
Displayed
the 16 status codes will be overwritten each time a new
status code occurs. This stored status code register can
be cleared from memory by using the Handset.
ACCESSING STORED STATUS CODES
WITH GE HANDSET
Key Switch Off
Push ESC and CONT
At The Same Time
Release ESC and CONT
Key
Status Code Displayed
Push CONT Key
Displays Battery
State-Of-Charge When
Fault Occurred
Push CONT Key
Display Hourmeter Reading
When Fault Occurred
Push CONT Key
Section 5.3.3 IT Family Handset, Plug Connections
and Outline Drawing
Handset Cable Part Number - 171B3990G4
38
Page
Hold Both the
Push ESC to
ESC and CONT
Erase Stored
Keys Down to
Data
Erase All 16
Stored Codes
Push ESC to
Erase Stored
Data
Push ESC to
Erase Stored
Data
"Y"Plug
November 2005

Advertisement

Table of Contents
loading

Table of Contents