Firman P03618 Operator's Manual page 13

Table of Contents

Advertisement

Available languages

Available languages

Add Engine Oil
NOTICE
NOTE:
Degrees Celsiusº(Outside)
Full Synthetic 5W-30
5W-30
Degrees Fahrenheitº(Outside)
1.Place generator on a flat, level surface.
2.Clean area around oil fill and remove yellow
oil fill cap/dipstick.
3.Wipe dipstick clean.
H
L
DRAIN PLUG
English
10W-40
10W-30
4.Using oil funnel, slowly pour contents of
provided oil bottle into oil fill opening to the
"H" mark on dipstick. Be careful do not
overfill. Overfilling with oil could cause the
engine to not start or hard starting.
5.Replace oil fill cap/dipstick and fully tighten.
6.Oil level should be checked prior to each use
or at least every 8 hours of operation. Keep oil
level maintained.
The engine is equipped with a low oil shut-off and
will stop when the oil level in the crankcase falls
below the threshold level.
NOTE:
We consider the first 5 hours of run time to be
the break-in period for the unit. During the break
in period stay at or below 50% of the running
watt rating and vary the load occasionally to allow
stator windings to heat and cool. Adjusting the
load will also cause engine speed to vary and help
seat piston rings.
Low oil shutdown
engine.
(H)
(L)
Page 11
Customer Service: 1-844-FIRMAN1

Advertisement

Table of Contents
loading

Table of Contents