TROUBLESHOOTING (continued)
PROBLEM
TUB LOSES AIR
• Air valve cap loose.
PRESSURE
• Air valve base loose.
• Hole, cut or split on spa tub.
LEAKING BETWEEN
• Spa control base inlet/outlet
SPA TUB
connections not securely tight.
CONNECTORS AND
• Spa control base inlet/outlet o-ring
CONTROL UNIT
missing/dirty.
CONNECTORS
SPA IS TOO NOISY
• Control base components not
IN FILTRATION
securely attached.
MODE ONLY
• Control base ground not level and
fi rm.
• Spa fi lter motor failed.
AIR PRESSURE
• Hose adaptor o-ring missing.
IS WEAK DURING
• Infl ation hose adaptor not securely
INFLATION
tighten.
• Connection between the hose
adaptor and blower infl ation outlet,
and between the infl ation hose and
infl ation valve are loose.
• Air blower failure.
AIR BUBBLES ARE
• O-ring missing between the control
NOT AS STRONG
base air outlet and spa tub air inlet
AS BEFORE
connections.
• Air connection nut is not securely
tight.
• Air bubble channel passage inside
the tub broken or leaking.
• Air blower failure.
If you continue to experience diffi culty, please contact our Consumer Service Department for
assistance. See separate "Authorized Service Centers" sheet.
S AVE THESE INSTRUCTIONS
(346PO) SPA ENGLISH 7.5" X 10.3" PANTONE 295U 08/10/2019
CAUSE
• Ensure air valve cap is securely closed.
• Fill up the spa tub with air then make sure the
air valve base is tighten, see "Spa Tub Air Valve
Fastening" section.
• Put liquid soap and water in a squirt bottle and
spray on seams. If there is a leak it will bubble.
After you fi nd the leak, clean and dry the leaking
area, then apply the repair patch that comes with
your spa.
• Tighten inlet and outlet connections.
• Coat the o-ring with petroleum jelly for water
proof.
• Remove grid from inside spa with a screwdriver,
ensure inlet/outlet O-ring is in place, clean and
not damaged.
• Ensure control panel, back cover and all inlet/
outlet are securely connected.
• Ensure ground is level, fi rm and smooth.
• Replace the failed fi lter motor with a new one.
• Ensure the o-ring is in place.
• Tighten/reinstall hose adaptor.
• Finger tighten during infl ation.
• If problem persists, contact Intex Service Center.
• Ensure the o-ring is in place.
• Finger tighten all nuts.
• Use repair patch to repair any puncture.
• If problem persists, contact Intex Service Center.