Remote Controller Buttons And Icons - Daikin EKHBRD014AAV1 Operation Manual

Indoor unit for air to water heat pump system and options
Hide thumbs Also See for EKHBRD014AAV1:
Table of Contents

Advertisement

Remote controller buttons and icons

8
5
6 23
7
9
12
10
22
21
32
27
25
28
26
1.
ON/OFF BUTTON
y
The ON/OFF button starts or stops the space heating.
Pressing the ON/OFF button consecutively too many times may
cause malfunction of the system (maximum 20 times per hour).
NOTE
Remark that pushing the
influence
Domestic water heating is only switched on or off
by means of the
storage schedule timer.
2.
OPERATION LED
0
The operation LED is lit during space heating operation. The
LED blinks if a malfunction occurs. When the LED is OFF, space
heating is inactive while the other operation modes can still be
active.
3.
OPERATION MODE ICONS
These icons indicate the current operation mode(s): space
heating (
h
), domestic water heating (
Within limits, different modes can be combined, e.g. space
heating and domestic water heating. The corresponding mode
icons will be displayed simultaneously.
If the domestic hot water tank is not installed, the
never be displayed.
4.
EXTERNAL CONTROL ICON
This icon indicates that the outdoor unit is working in a forced
operation. As long as this icon is displayed, the remote controller
cannot be operated.
5.
DAY OF THE WEEK INDICATOR
This indicator shows the current day of the week.
When reading or programming the schedule timer, the indicator
shows the set day.
6.
CLOCK DISPLAY
8
The clock display shows the current time.
When reading or programming the schedule timer, the clock
display shows the action time.
7.
SCHEDULE TIMER ICON
This icon indicates that the schedule timer is enabled.
8.
ACTION ICONS
q
These icons indicate the programming actions for each day of
the schedule timer.
9.
OFF ICON
x
This icon indicates that the OFF action is selected when
programming the schedule timer.
10. INSPECTION REQUIRED
These icons indicate that inspection is required on the
installation. Consult your dealer.
Operation manual
3
15
17
3
16
2
1
y
button has no
on
the
domestic
water
w
button and/or disabling the
h
,
w
,
s
w
) or quiet mode (
w
e
1234567
p
k
and
l
11. TEMPERATURE DISPLAY
The display shows the current temperature of the installation
either leaving water temperature or actual room temperature.
When changing the room temperature set point, the set point will
be flashing for 5 seconds and then return to the actual room
temperature.
12. SETTING
4
Not used. For installation purposes only.
14
20
13. NOT AVAILABLE
18
11
This icon is displayed whenever a non-installed option is
19
13
addressed or a function is not available. A function not available
can mean insufficient permission level or can mean that a slave
remote controller is used (see installation manual).
33
24
31
Operation ON/OFF
30
Domestic water heating operation
29
ON/OFF
Setting the leaving water temperature
Setting the room temperature
Quiet mode ON/OFF
Weather dependent set point operation
ON/OFF
Setting the clock
Programming the schedule timer
heating.
Schedule timer operation ON/OFF
Field settings
Error code display
Test operation
= operable
14. DEFROST/START UP MODE ICON
This icon indicates that the defrost/start up mode is active.
15. COMPRESSOR ICON
This icon indicates that the compressor in the outdoor unit of the
installation is active.
s
).
16. HEATER STEP
If the heater kit option is installed,
is operating.
icon will
17. PUMP ICON
This icon indicates that the circulation pump is active.
18. OUTDOOR TEMPERATURE DISPLAY
When this icon is flashing, the outdoor ambient temperature is
displayed. Refer to
more information.
19. WEATHER DEPENDENT SET POINT ICON
This icon indicates that the controller will adapt the leaving water
temperature set point automatically, based on the outdoor
ambient temperature.
20. TEMPERATURE ICON
This icon is displayed when the actual room temperature or
room temperature set point are shown.
The icon is also displayed when the temperature set point is set
in schedule timer programming mode. Refer to
read-out mode" on page 9
21. TEST OPERATION ICON
This icon indicates that the unit runs in test mode.
22. FIELD SET CODE
This code represents the code from the field set list. Refer to the
"Field settings table" on page
23. ERROR CODE
This code refers to the error code list and is for service purposes
only. Refer to the error code list in the installation manual.
9
$
n
Master
d
ç
(
(
icon indicate that the heater
é
u
"Temperature read-out mode" on page 9
b
for more information.
t
;
16.
:
Indoor unit for air to water heat pump system and options
Permission
Slave
level 2
level 3
for
a
"Temperature
EKHBRD011~016AAV1+Y1
4PW54466-1C

Advertisement

Table of Contents