Download Print this page

Delta sync 24V 100W Series Technical Data Sheet page 5

Din rail power supply

Advertisement

TECHNICAL DATASHEET
Sync DIN Rail Power Supply
24V 100W Series / DRS-24V100W1A
EMC
EMC / Emissions
Component Power Supply for General Use
Immunity to
Electrostatic Discharge
Radiated Field
Electrical Fast Transient / Burst
Surge
Conducted
Power Frequency Magnetic Fields
Voltage Dips and Interruptions
Low Energy Pulse Test (Ring Wave)
Harmonic Current Emission
Voltage Fluctuation and Flicker
1) Criteria A: Normal performance within the specification limits
2) Criteria B: Temporary degradation or loss of function which is self-recoverable
3) Asymmetrical: Common mode (Line to earth)
4) Symmetrical: Differential mode (Line to line)
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
5
www.DeltaPSU.com (March 2016, Rev. 00)
/ DRS-24V100W1N
Model Number
DRS-24V100W1A☐
Generic Standards: EN 61000-6-3, EN 61000-6-4
CISPR 22, EN 55022 EN 55011, FCC Title 47: Class B
EN 61204-3
Generic Standards: EN 55024, EN 61000-6-1, EN 61000-6-2
IEC 61000-4-2
Level 3 Criteria A
Air Discharge: 8kV
Contact Discharge: 6kV
IEC 61000-4-3
Level 3 Criteria A
80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation
1.4GHz-2GHz, 3V/M with 1kHz tone / 80% modulation
2GHz-2.7GHz, 1V/M with 1kHz tone / 80% modulation
IEC 61000-4-4
Level 3 Criteria A
2kV
IEC 61000-4-5
Level 3 Criteria A
Common Mode
Differential Mode
IEC 61000-4-6
Level 3 Criteria A
150kHz-80MHz, 10Vrms
1)
IEC 61000-4-8
Criteria A
30A/Meter
IEC 61000-4-11
0% of 100Vac, 20ms
0% of 100Vac, 5000ms
40% of 100Vac, 200ms
70% of 100Vac, 10ms
70% of 100Vac, 500ms
0% of 240Vac, 20ms
0% of 240Vac, 5000ms
40% of 240Vac, 200ms
70% of 240Vac, 500ms
IEC 61000-4-12
Level 3 Criteria A
Common Mode
Differential Mode
IEC/EN 61000-3-2, Class A
IEC/EN 61000-3-3
DRS-24V100W1N☐
1)
1)
1)
1)
3)
: 2kV
4)
: 1kV
1)
1)
Criteria A
2)
Criteria B
2)
Criteria B
1)
Criteria A
1)
Criteria A
1)
Criteria A
2)
Criteria B
1)
Criteria A
1)
Criteria A
1)
3)
: 2kV
4)
: 1kV

Advertisement

loading