Hitachi KP-M1E/K Operation Manual page 31

B/w ccd
Table of Contents

Advertisement

・  A ttenuation of video signal due to used cable
Attenuation due to optional cables C-501KSM and C-102KSM is shown below.
Attenuation is proportionate to the cable length.
Characteristic impedance is kept at constant even at cable length change.
Attenuation due
to cable length(dB)
The video bandwidth obtained by the KP-M1A is up to approximately 7MHz.
KP-M1A
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Cable
Attenuation at 4MHz
length
50dB/Km
1m
0.05
2m
0.1
5m
0.25
10m
0.5
Attenuation at 7MHz
70dB/Km
0.07
0.14
0.35
0.7