Hitachi KP-M1E/K Operation Manual page 13

B/w ccd
Table of Contents

Advertisement

(2) Difference between the restart/reset (R/R) function and the Field-on-Demand (FD) function.
R.R.
Restart
of
sync
signal only
FD
(Fixed shutter)
Reset
of
sync
signal and start of
shutter
R/R function: The desired image is after one field with respect to the input pulse.
FD function: The desired image is immediately after the input pulse.