Install The Hood (Ez1 Bracket) - Broan BCDJ Series Installation Use And Care Manual

Table of Contents

Advertisement

N
1 ] Run house power cable between service panel and hood location.
2 ] There are 2 pairs of recessed holes on each side of the top of the hood (on rear: A and B,
HORIZONTAL EXHAUST INSTALLATION
3 ] Temporarily hang the hood on the brackets using its (2) recessed REAR HOLES (A and B).
4 ] Unhook the rear holes from the brackets and hang the hood using its (2) recessed FRONT
VERTICAL EXHAUST INSTALLATION
5 ] Hang the hood on the brackets using the (2) recessed FRONT HOLES (C and D). While
6 ] Connect ductwork to hood and use metal foil duct tape to make joints secure and air-tight.
16

Install the Hood (EZ1 Bracket)

OTE:
The following procedure applies to both frame or frameless cabinet installations.
on front C and D on illustration below); these holes allow the range hood to hang on the
brackets (previously installed).
While holding the hood, run the house power cable into the hood through the strain relief
previously installed in step 6 on page 11.
HOLES (C and D). While holding the hood, go to step 6.
holding the hood, tighten an appropriate strain relief, 1/2" diameter (not included) to the
power cable, then insert the strain relief in the knockout hole.
Make sure the damper assembly (or round duct plate) enters the ductwork and that the
damper opens and closes freely.
A
C
A
DUCTED INSTALLATION ONLY
D
B
B

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ncdj seriesBcdj130Bcdj130blBcdj130ssBcdj142ssBcdj136bl

Table of Contents