VSM PRESET ADJUST SETTING
Measuring
Item
instrument
VSM PRESET
Remote
setting
control unit
1.CONT.
COOL
32"
NORMAL
WARM
COOL
28"
NORMAL
WARM
Test point
Ad justment part
1. CONT .
2. BRIGHT
3. SHARP
4. COLOUR
5. HUE
6. WDR R
7. WDR G
8. WDR B
2.BRIGHT
3.SHARP
+16
0
-10
0
0
-10
-13
0
-12
+13
0
-12
-3
0
-12
-13
0
-12
SETTING VALUES OF VSM PRESET
1.
Select COOL with the MENU key of the remote control unit.
2.
Select 5.VSM PRESET from the SERVICE MENU.
3.
Adjust the FUNCTION UP/DOWN ( / ) and -/+ ( / )key to
bring the set values of 1.CONT ~ 8. WDR B to the values
shown in the table.
4.
Press the MENU key and memoriz e the s et value.
5.
Respectively s elect the VSM PRESET mode for NORMAL and
WARM, and make similar adjustment as in 3 above.
6.
Press the MENU key and memoriz e the s et value.
* Refer to OPERATING INSTRUCTIONS for the PICTURE
MODE.
4.COLOUR
5.HUE
+1
0
0
0
-1
0
0
0
0
0
-1
0
No. 51945
AV32H20EUS
AV28H20EUS
AV28H20EUB
Description
6.WDR R
7.WDR G
8.WDR B
-27
-12
0
0
+5
0
-28
-12
0
0
+4
0
0
0
0
0
0
0