6 Configuration

#
5
Reinstall the faceplate onto the wallplate.
Be careful NOT to pinch the wiring when attaching the
frontplate to the unit.
4A From the rear
PCB
a
b
4C From the top
a
b
PCB
b
a Notch this part for the wiring to pass through with nippers
etc.
b Secure the wiring to the front part of the casing using the
wiring retainer and clamp.
To connect the bivalent signal for third-party gas
boiler
1 Connect the bivalent signal for third-party gas boiler to the
appropriate terminals as shown in the illustration below.
X2M
8
7
a
Bivalent signal for third-party gas boiler
2 Fix the cable with cable ties to the cable tie mountings.
Installation manual
20
Action
4B From the left
PCB
a
b
4D From the top centre
a
b
PCB
b
L N
a
To connect the external pump
NOTICE
External pump. In case of third-party gas boiler, you must
install
the
mandatory
EKADDONJH2 (= connection kit for third-party gas boiler).
This includes connecting the external pump to the outdoor
unit. For installation instructions, see the installation
manual of the connection kit.
6
Configuration
6.1

Overview: Configuration

This chapter describes what you have to do and know to configure
the system after it is installed.
NOTICE
This chapter explains only the basic configuration. For
more detailed explanation and background information,
see the installer reference guide.
INFORMATION
Gas boiler. Depending on the installed gas boiler, settings
will be visible/invisible.
▪ By default, only the settings applicable for the third-
party gas boiler are displayed.
▪ When the unit detects communication from the
*HY2KOMB28+32AA gas boiler, all settings applicable
for
the
*HY2KOMB28+32AA
automatically displayed.
Why
If you do NOT configure the system correctly, it might NOT work as
expected. The configuration influences the following:
▪ The calculations of the software
▪ What you can see on and do with the user interface
How
You can configure the system via the user interface.
▪ First time – Quick wizard. When you turn ON the user interface
for the first time (via the outdoor unit), a quick wizard starts to help
you configure the system.
▪ Afterwards. If necessary, you can make changes to the
configuration afterwards.
INFORMATION
When the installer settings are changed, the user interface
will request to confirm. When confirmed, the screen will
shortly turn OFF and "busy" will be displayed for several
seconds.
Accessing settings – Legend for tables
You can access the installer settings using two different methods.
However, NOT all settings are accessible via both methods. If so,
the corresponding table columns in this chapter are set to N/A (not
applicable).
Method
Accessing settings via the breadcrumb in the
menu structure.
Accessing settings via the code in the
overview settings.
Daikin Altherma H Hybrid – Heat pump module
options
EKADDONJH
and
gas
boiler
are
Column in tables
#
For example:
[A.2.1.7]
Code
For example: [C-07]
EJHA04AAV3
4P530607-1D – 2020.02

Advertisement

Table of Contents
loading

This manual is also suitable for:

Altherma ejha04aav3Altherma h hybridEjha04aav3Ejha-av3

Table of Contents