Domestic Hot Water Control - Daikin Altherma EJHA-AV3 Installation Manual

H hybrid heat pump module
Hide thumbs Also See for Altherma EJHA-AV3:
Table of Contents

Advertisement

6 Configuration
If...
Space heating is done
And...
by...
Gas boiler only
(only applicable in case of
*HY2KOMB28+32AA gas boiler)
Combination of outdoor unit and
gas boiler
(only applicable in case of
*HY2KOMB28+32AA gas boiler)
Field setting [C-0B] defines whether ΔT control is enabled. The main
pump will only run according to ΔT control if [C-0B] is set to 1 and
space heating is done by the outdoor unit only. If the pump runs
according to ΔT control:
If Emitter type [2-0C]=...
0: Underfloor heating
1: Fancoil unit
2: Radiator
INFORMATION
Changing these settings can result in discomfort. Refer to
the installer reference guide for more information.
Leaving water temperature: Modulation
#
Code
[A.3.1.1.5]
[8‑05]
Leaving water temperature modulation:
▪ 0 (No): Disabled
▪ 1 (Yes): Enabled. The leaving water
temperature is calculated according
to the difference between desired
and actual room temperature. This
allows
heat  pump
required capacity and results in less
start/stop cycles of the heat  pump
and more economic operation.
This function is only applicable in case
of room thermostat control ([C-07]=2).
N/A
[8-06]
Leaving water temperature maximum
modulation:
Range: 0°C~10°C
Requires modulation to be enabled.
This is the value by which the desired
leaving water temperature is increased
or lowered.
INFORMATION
When leaving water temperature modulation is enabled,
the weather‑dependent curve needs to be set to a higher
position than [8-06] plus the minimum leaving water
temperature setpoint required to reach a stable condition
on the comfort setpoint for the room. To increase
efficiency, modulation can lower the leaving water setpoint.
By setting the weather‑dependent curve to a higher
position, it cannot drop below the minimum setpoint. See
the illustration below.
Installation manual
24
Then the main pump runs...
At maximum pump speed.
Then the target ΔT in heating
is...
Variable according to [1-0B].
Fixed (10°C).
Description
better
matching
of
the
capacity
to
actual
T t
+[8-06]
−[8-06]
a
Weather-dependent curve
b
Minimum leaving water temperature setpoint required to
reach a stable condition on the comfort setpoint for the
room.
Leaving water temperature: Emitter type
#
Code
Emitter type:
[A.3.1.1.7]
[9‑0B]
Reaction time of the system:
▪ 0: (Quick)
Example: Small water volume and
fan coils.
▪ 1: (Slow)
Example: Large water volume, floor
heating loops.
Depending on the system water volume
and the heat emitters type, the heat up
of a space can take longer. This setting
can compensate for a slow or a quick
heating system by adjusting the unit
capacity during the heat up cycle.
Quick heat up function
#
Code
N/A
[C‑0A]
Indoor quick heat up function:
▪ 0: OFF.
▪ 1: On.
Only applicable in case of room
thermostat control. The function will
start up the gas boiler when the actual
room temperature is 3°C lower than the
desired room temperature. The large
boiler capacity can quickly boost up the
room temperature to the desired
temperature. This can be useful after
long periods of absence or after a
breakdown of the system.
Leaving water temperature: Delta T source
#
Code
[A.3.1.3.1]
[1‑0B]
Heating: required temperature
difference between entering and
leaving water.
In case a minimum temperature
difference is required for the good
operation of the heat emitters in heating
mode.
Range: 3°C~10°C
6.2.5

Domestic hot water control

Only applicable in case of *HY2KOMB28+32AA gas boiler, and an
optional domestic hot water tank is installed.
This is always applicable for Switzerland.