Pioneer CDX-FM677-X1N/ES Service Manual page 47

Universal multi-cd system
Table of Contents

Advertisement

- Flow Chart
4
Sourse CD
Power ON
(Adjustment for T.Offset)
TRK
MIN
00 00 00
Display
Power OFF
BAND
Focus Close/
S Curve Check
TRK
MIN
91 91 91
Display
Power OFF
BAND
T.Close and
F,T AGC and
RF AGC and
Fit Servo
Power OFF
BAND
Power OFF
BAND
< Mechanism test mode in >
9
*9
<ELV,TRAY select>
TYP
*1
Display
Focus Close
*2
Display
00 00 00
(99 99 99)
*3
F.Offset Display
F.Cancel Value = {Top Rank 8bit of Set Value (7F [H] to 80 [H] ) + 128} / 4
Single TR/32TR/100TR
*4
*5
Single TR
Display
9x(8x):91(81)
*6
CRG Move, 100TR Jump Only
6
Test Mode In
Reset
SOURCE
BAND
9
Power ON
SEC
(Not adjustment for T.Offset)
TRK
MIN
SEC
99 99 99
Display
9
12
*2
Focus Mode
Select
SEC
TRK
MIN
SEC
0x 0x 0x
Display
7
12
T. Close and
RF AGC Coefficient Display/
Fit Servo
Rough Servo and RF AGC
7
9
*7
F, T, RF AGC/
F, T AGC and
F.Bias Display Select
RF AGC
TRK
MIN
SEC
7
72 00 00
Display
12
FF
*10
*11
<Operation mode
<Shift >
select >
+6dB
+12dB
06 06 06
12 12 12
S Curve Check
01 01 01
RF.Offset Display
F.Cansel Display
= 63 [D] to (32 [D] ) to 00 [D]
32TRK
100TRK
CRG Move
92(82)
93(83)
8
*1
RF AMP Gain Select
TRK
MIN
SEC
GG GG GG
7
TRK+
*8
<Tracking Servo Close>
CRG+
TRK
MIN
SEC
TRK
MIN
SEC
00 00 00
00 00 00
or
or
TRK
MIN
SEC
TRK
MIN
SEC
99 99 99
99 99 99
TRK+
9
CRG+
TRK
MIN
SEC
8x 8x 8x
Display
or
TRK
MIN
SEC
9x 9x 9x
12
TRK+
*5
*4
CRG−/TR Jump−
CRG/TR Jump NO.
CRG+/TR Jump+
Select
Display
REV
BAND
*12
<Shift >
<Mechanism test
mode out >
*7
TRK, MIN, SEC
Voltage of CRG Motor = 2 [V]
*8
*9
ELV motor select
72
8ms pulse drive
*10
72
48ms pulse drive
72
94(84)
*11
ELV select
TRAY select : TRAY out
*12
ELV select
TRAY select : TRAY in
CDX-FM677,FM673
New test mode
12
TRK-
8
*8
*3
Auto Adjustment
CRG−
Display Select
TRK
MIN
SEC
00 00 00
or
TRK
MIN
SEC
99 99 99
TRK-
8
T.Balance
CRG−
Adjustment
TRK
MIN
SEC
8x 8x 8x
or
TRK
MIN
SEC
9x 9x 9x
Tracking
Open
TRK-
8
*4
*6
TRK
MIN
SEC
8x 8x 8x
Display
or
8
TRK
MIN
SEC
9x 9x 9x
Tracking
Open
TRK
MIN
SEC
8x 8x 8x
or
TRK
MIN
SEC
9x 9x 9x
TRK
MIN
SEC
Display
F.AGC Gain
T.AGC Gain
(F,T.AGC Gain = (Present Value/Initial Value) × 20)
TRAY motor select
00
0X
72
10
0X
Display
24ms pulse drive
00
00
72
00
01
72
Display
100ms pulse drive
10
00
72
10
01
72
Display
: ELV dowm (Disc 12
1)
: ELV up (Disc 1
12)
RF AGC Gain
DC drive
00
02
DC drive
10
02
47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cdx-fm677-x1n/ucCdx-fm677Cdx-fm673Cdx-fm673-x1n/uc

Table of Contents