LG LMXS27676D Service Manual page 50

Table of Contents

Advertisement

8-13. Water mode doesn't work
Symptom
1. Water mode
doesn't work
(PR)
1. Check the loose connection
2. Check the resistance valve
(BL)
CON2
Check Point
LEVER S/W
Pushing
CON2
nd
th
2
pin ~11
pin
Pushing
Pilot Valve
Water valve
Voltage [V]
112~115V
Not
0~2V
Resistance [Ω]
360~420
360~420

Advertisement