CAUTION: Make sure that the motor housing is taped to
the mold, if not positioned correctly the cover will not fit
properly.
3-15 SUB PWB FOR WORKING DISPENSER
1) Disconnect the wire harness.
2) Remove 1 screw from PWB and replace with new PWB.
3-16 CAP DUCT MOTOR REPLACEMENT
1) Separate the Housing of the Cap Duct Motor.
2) Unscrew 3 screws to disassemble the motor.
3) When replacing the motor, check the position of the door
duct and the link for proper fit.
4) Insert 2 screws.
5) Push housing aside.
- 1 -
Duct Door
Link
Cap Duct Motor
NG Position