Charnwood SLX20 Operating And Installation Instructions

Charnwood slx20 multi-fuel roomheater operating and installation instructions manual

Advertisement

Quick Links

CHARNWOOD
SLX20 Multi-Fuel
Roomheater
Operating
and

Installation Instructions

Bishops Way, Newport, Isle of Wight, PO30 5WS, U.K.
Tel: +44(0)1983 537799 Fax: +44(0)1983 537788
E-Mail: charnwood@ajwells.co.uk Internet: www.charnwood.com

Advertisement

Table of Contents
loading

Summary of Contents for Charnwood SLX20

  • Page 1: Installation Instructions

    CHARNWOOD SLX20 Multi-Fuel Roomheater Operating Installation Instructions Bishops Way, Newport, Isle of Wight, PO30 5WS, U.K. Tel: +44(0)1983 537799 Fax: +44(0)1983 537788 E-Mail: charnwood@ajwells.co.uk Internet: www.charnwood.com...
  • Page 2: Table Of Contents

    Commissioning ....11 Overall Dimensions ....11 Bishops Way, Newport, Isle of Wight, PO30 5WS, U.K. Tel: +44(0)1983 537799 Fax: +44(0)1983 537788 E-Mail: charnwood@ajwells.co.uk Internet: www.charnwood.com...
  • Page 3: General Points

    PEAT Ensure that the peat is well dried before use. Burning wet peat will give rise to heavy tar deposits and reduce outputs. CHARNWOOD SLX20 PETROLEUM COKE IS NOT SUITABLE FOR USE ON THIS APPLIANCE, ITS USE WILL INVALIDATE THE At first you may find it helpful to try several fuels to find the most suitable.
  • Page 4: Door Operation

    When closing the doors do not use excessive force. MULTIFUEL GRATE Your Charnwood is fitted with a multifuel grate which enables solid fuel, wood and peat to be burned equally effectively.
  • Page 5: Riddling

    Aerosol spray cleaners should not be used near the appliance whilst it is under fire. Page 5 SLX20 9.03 CLEANING COAL...
  • Page 6: Chimney Sweeping

    The airwash relies on a supply of heated air to keep the Page 6 SLX20 9.03...
  • Page 7 It is also important that the chimney draw is sufficient and that it is not affected by down-draught.Whenthechimneyis warm a draught reading of at least 2.5mm (0.10 inches) water gauge should be obtained. Page 7 SLX20 9.03...
  • Page 8: Health & Safety Precautions

    Solid Fuel burning appliances, flues and chimney must be observed. PERFORMANCE The rated output for the SLX20 is 5.4 kW (18500btu/h) to the room. This is the output obtained burning smokeless fuel with the doors closed over a 4 hourly re-fueling interval.
  • Page 9: Fitting The Fire

    One of the original sidebricks is fitted on the other side, and the rear brick is discarded. The firebricks are held in position by the retaining brackets. Feed and Expansion Tank Page 9 SLX20 9.03 FITTING THE OPTIONAL ADD-IN BOILER 22mm Open Vents...
  • Page 10: Flue Connections & Infilling

    Fig. 5. Typical Installation Flap Just Closed With Knob Set To Minimum Locking Nut Thermostat Flap Fig. 6. Thermostat Setting Page 10 SLX20 9.03 Flaunching Take Flue Pipe Up To Narrowest Part Of Chimney. 150° Elbow Part No. 010/AV12 Vermiculite...
  • Page 11: Pre Lighting Check

    On completion of the installation and commissioning please leave the operating instructions with the customer and advise on the use of the appliance. Knock outs for optional boiler either side 150° SLX20 Dimensions (All dimensions are in mm) Page 11 SLX20 9.03...

Table of Contents

Save PDF