WARNING There must not be an extractor fan fitted in the same room as this appliance as this can cause the appliance to emit smoke and fumes into the room.
Care should be taken to ensure that ash is cool before emptying it into plastic liners or bins. To make ash removal easier there is a special Charnwood ash carrier available. This may be purchased from your supplier or, in case of difficulty, from ourselves.
Page 6
blockage, and clean if required. D) Do not attempt to relight fire until cause of fume has been identified, if necessary seek professional advice. The most common cause of fume emission is flueway or chimney blockage. For your own safety these must be kept clean.
If there is a possibility of disturbing any asbestos in the course of installation then please use appropriate protective equipment. There must not be an extractor fan fitted in the same room as the appliance as this can cause the appliance to emit fumes into the room.
This Dimension Is The Minimum Level Area Required To Enable The Doors To Be Opened. For Overall Sizes Of Hearth See The Section Titled "Hearth". 405 mm 400 mm Minimum Fig. 4. Limiting Dimensions Of Hearth The shaded area on the face of the surround is the minimum flat area required.
FLUE CONNECTION AND INFILLING Make the flue connection with the special 150°elbow part no. 010/AV12. Please note that this item is ordered separately from the appliance. The legs of the elbow may be cut on site to suit the chimney. Also note that the legs of the elbow are different lengths to enable some situations to be catered for by turning...