  • Page 2: General Points

    OPERATING INSTRUCTIONS FOR THE CHARNWOOD DX20i MKII GENERAL POINTS Before lighting the fire check with the installer that the work and checks described in the installation instructions have been carried out correctly and that the chimney has been swept, is sound, and free from any obstructions.
  • Page 3: Multifuel Grate

    Open the main doors Open the ashpit door Close the ashpit door Close the main doors MULTIFUEL GRATE Your Charnwood is fitted with a multifuel grate which enables solid fuel, wood and peat to be burned equally effectively. The grate has two positions. One for solid fuel, the other for wood and peat.
  • Page 4: Ash Clearance

    Care should be taken to ensure that ash is cool before emptying it into plastic liners or bins. To make ash removal easier there is a special Charnwood ash carrier available. This may be purchased from your supplier or, in case of difficulty, from ourselves.
  • Page 5: Cleaning And Maintenance

    THROAT PLATE AND FLUEWAY CLEANING It is important that the throat plate and all the appliance flueways are kept clean. When burning smokeless fuels they should be cleaned monthly. When burning other fuels they should be cleaned at least once a week, and more frequently if necessary.
  • Page 6 Fire Blazing Out Of Control. Check that: a) the doors are tightly closed, b) the thermostat knob is turned down to the minimum setting, c) the air inlet damper is closed (at the bottom left of the appliance), and that it is not prevented from closing completely by a piece of ash, d) a suitable fuel is being used, e) the door seals are in good...
  • Page 7: Health And Safety Precautions

    CHARNWOOD DX20i INSTALLATION HEALTH AND SAFETY PRECAUTIONS WARNING Please take care when installing the appliance that the requirements of the Health and Safety at Work Act 1974 are met. Some types of fire cement are caustic and should not be allowed to come into contact with the skin.
  • Page 8: Preparation Of Fireplace

    appliance. In some situations it may be necessary to shield the beam or mantelpiece to protect it. PREPARATION OF FIREPLACE Before fitting the appliance into an existing fireplace remove the fireback and any loose in-fill material. The hearth, surround and opening for the appliance must conform with Figs.
  • Page 9: Flue Connection And Infilling

    same side as the boiler tappings. One of the original side firebricks is fitted on the other side, and the rear firebrick is discarded. The firebricks must be fire cemented into position, wetting the firebox will improve the adhesion. Replace the back fireplate, the side fireplates, the front firebar and the throat plate.
  • Page 10: Pre Lighting Check

    The free inset method of installation may be used instead of infilling. Details are available on request. THERMOSTAT Before lighting the fire check the cold setting distance of the thermostat. With the control knob at the minimum setting the flap should be just closed as shown in Fig.
  • Page 11 Optional Boiler May BeFitted With The1" B.S.P . MaleTappings On TheLeft Or TheRight. 150º Charnwood DX20i M kI I Overall Dimensions (Dimensions are in mm) Page 11 HV 7/96...