Charnwood Country 15B Operating And Installation Instructions

Roomheater with boiler

Advertisement

CHARNWOOD
COUNTRY 15B
Roomheater with Boiler
Operating
and

Installation Instructions

C H A R N W O O D
B i s h o p s W a y , N e w p o r t , I s l e o f W i g h t P O 3 0 5 W S , U n i t e d K i n g d o m
T : + 4 4 ( 0 ) 1 9 8 3 5 3 7 7 9 9
F : + 4 4 ( 0 ) 1 9 8 3 5 3 7 7 8 8
c h a r n w o o d @ a j w e l l s . c o . u k
w w w . c h a r n w o o d . c o m

Advertisement

Table of Contents
loading

Summary of Contents for Charnwood Country 15B

  • Page 1: Installation Instructions

    CHARNWOOD COUNTRY 15B Roomheater with Boiler Operating Installation Instructions C H A R N W O O D B i s h o p s W a y , N e w p o r t , I s l e o f W i g h t P O 3 0 5 W S , U n i t e d K i n g d o m...
  • Page 2: Door Operation

    (see Fig.1) MULTIFUEL GRATE Your Charnwood stove is fitted with a multifuel grate which enables both solid fuels and wood to be burned equally effectively. The grate has two positions:-...
  • Page 3: Overnight Burning

    When loading the stove take care not to smother the fire, instead fill the firebox in two stages waiting between Page 2 Country 15B 09/03 each stage for the flames to appear above the fire. After a period of slumbering always...
  • Page 4: Chimney Sweeping

    Page 3 Country 15B 09/03 e) that an extractor fan is not fitted in the same room as the stove. f) there is sufficient draw in the chimney, (once the chimney is warm a draught reading of at least 0.10 inches...
  • Page 5 (see Fig. 3.) and that it is not distorted. c) the door seals are in good condition. Page 4 Country 15B 09/03 d) If the hot water goes cold when the pump is turned on, or if some radiators are hotter than others, then the system...
  • Page 6: Hearth And Fire Surround

    Regulations regarding the installation of Solid Fuel burning appliances, flues and chimneys must also be observed. PERFORMANCE The output of the Country 15B is 13.0 kW (44,400 Btu/h) to water and 2.5 kW (8,500 Btu/h) to the room. The outputs were obtained burning smokeless fuel over a four hourly re- fuelling cycle with the doors closed.
  • Page 7: System Controls

    Fig. 6. Typical Central Heating & Hot Water System Using 3 Tappings Gravity Return (28mm Pipe) Central Heating Return Fig. 7. Injector Tee. Page 6 Country 15B 09/03 Cold Water Tank Overflow Domestic Hot Water Draw Off Drain Cock Central Heating Flow Circulating Pump...
  • Page 8: Connections To Flues

    This may either be in the actual brickwork of the chimney or in the register plate. Page 7 Country 15B 09/03 Back of the Stove Blanking Plate Clamping Plate Blanking Plate...
  • Page 9 Also check all joints and seals. The central heating pump should be Boiler tappings are 1" BSP Female Country 15B Dimensions (All dimensions are in mm) Page 8 Country 15B 09/03 adjusted to give the correct water flow against the circuit resistance and the system should be correctly balanced.
  • Page 10 Item 24 has been replaced by items 51 & 52 but they are not interchangeable. Description 002/FV01 Left Hand Door 002/FV02 Right Hand Door 002/CH12B Flue Collar 009/CO15B/A Firebox / Boiler Assy (Country 15B) 012/TW09 Blanking Plate 002/TW34 Riddler Knob & Lever 008/FW48 Thermostat 008/FV49 Thermostat Flap 008/BW50...
  • Page 11 Your Local Charnwood Dealer C H A R N W O O D B i s h o p s W a y , N e w p o r t , I s l e o f W i g h t P O 3 0 5 W S , U n i t e d K i n g d o m...

Table of Contents