Symptom
Remedy
Noisy, intermittent, or dis-
Sometimes a video deck may output a noisy video signal (during scanning, for
torted picture.
example), or the video quality may just be poor (with some video game units,
for example). The picture quality may also depend on the settings, etc. of your
display device. Switch off the video converter and reconnect the source and
display device using the same type of connection (component or composite),
then start playback again.
Video signals are not output
When a monitor only compatible with resolutions of 480i is connected to the
from the component terminal.
component terminal and another monitor is connected to the HDMI terminal,
the video signals may not be output to the monitor connected to the compo-
nent terminal. If this happens, do the following:
— Turn off the power of the monitor connected to the HDMI terminal.
— Change the VIDEO PARAMETER menu RES setting (see Setting the Video
options on page 52 ).
— Video signals from the HDMI terminal cannot be output to the component
terminals. Input the video signals from the player or other source to the com-
posite or component terminals. When using the component terminal, assign it
at Input Setup (see The Input Setup menu on page 28 ).
The picture's movement is
When Resolution under VIDEO PARAMETER is set to 1080/24p, the picture
unnatural.
may not be displayed properly for some source materials. In this case, set the
resolution to something other than 1080/24p (page 52).
Settings
Symptom
Remedy
The Auto MCACC Setup con-
The ambient noise level may be too high. Keep the noise level in the room
tinually shows an error.
as low as possible (see also Problems when using the Auto MCACC Setup on
page 27 ). If the noise level cannot be kept low enough, you will have to set up
the surround sound manually (page 69).
When using only one surround back speaker, connect it to the SURROUND
BACK L (Single) terminals.
To use a 5.1-channel speaker set, use the surround speakers for the surround
channel, not the surround back channel.
Make sure there are no obstacles between the speakers and the microphone.
If Reverse Phase is displayed, try the following:
— The speaker's wiring (+ and –) may be inverted. Check the speaker con-
nections.
— Depending on the type of speakers and their installation conditions,
Reverse Phase may be displayed even if the speakers are properly connected.
If this happens, select GO NEXT and continue.
— If the speaker is not pointed to the microphone (listening position) or when
using speakers that affect the phase (dipole speakers, reflective speakers,
etc.), it may not be possible to properly identify the polarity.
Symptom
Remedy
After using the Auto MCACC
There may have been some low frequency noise in the room from an air-
Setup, the speaker size setting
conditioner, motor, etc. Switch off all other appliances in the room and use
is incorrect.
Auto MCACC Setup again.
Depending on a number of factors (bass reproduction capabilities of the
speakers, room size, speaker placement, etc.) this may occur in some cases.
Change the speaker setting manually in Speaker Setting on page 69 , and use
the ALL (Keep SP System) option for the Auto MCACC menu in Automatic
MCACC (Expert) on page 62 if this is a recurring problem.
Can't adjust the Fine Speaker
Check that the speakers are all in phase (make sure the positive (+) and nega-
Distance setting properly.
tive (–) terminals are matched up properly).
The display shows KEY LOCK
With the receiver in standby, press u STANDBY/ON for about 10 seconds
ON when you try to make
while holding down SPEAKERS to disable the key lock.
settings.
Most recent settings have been
The power cord was disconnected from the wall while adjusting this setting.
erased.
Settings are only stored if all the zones are turned off. Turn off all the zones
before unplugging the power cord.
The various system settings
Do not pull out the power cord while conducting the settings. (The settings
are not stored.
will be stored when both the main zone and sub zone turn off. Turn off all
zones before pulling out the power cord.)
Certain listening modes or
When Operation Mode is set to Basic, the Pioneer-recommended settings
HOME MENU items cannot be
are made and not all of the functions can be used. To use all of the functions
selected.
without restrictions, set Operation Mode to Expert (see Operation Mode
Setup on page 28 ).
Professional Calibration EQ graphical output
Symptom
Remedy
The reverb characteristics
There are cases where the graph does not appear flat (even when selecting
graph after EQ calibration does
ALL CH ADJ in the Auto MCACC Setup) due to adjustments made to compen-
not appear entirely flat.
sate for room characteristics to achieve optimal sound.
Areas of the graph may appear identical (before and after) when there is little
or no adjustment needed.
The graph may appear to have shifted vertically when comparing before and
after measurements.
EQ adjustments made using
Despite level adjustments being made, the filters used for analysis may not
the Manual MCACC setup
display these adjustments in the reverb characteristics graph after EQ calibra-
do not appear to change the
tion. However, these adjustments are taken into account by the filters dedi-
reverb characteristics graph
cated to overall system calibration.
after EQ calibration.