TABLE OF CONTENTS 0 TABLE OF CONTENTS Page General contents 1 CHARACTERISTICS OF THE INSTALLATION ENVIRONMENT 1.1 Preliminary instructions 2 FITTING 2.1 Handling and Unpacking 2.2 Connection to the electric network 2.3 Packing-list USER INSTRUCTIONS 3.1 Directions 3.2 Allowed Uses 4 DESCRIPTION OF THE MACHINE 4.1 Technical features 4.2 Description of the main elements...
CHAP 1 - CHARACTERISTICS OF THE INSTALLATION ENVIRONMENT 1.1 Preliminary directions Installation must be carried out by following the instructions contained in this handbook and only by specialized technical personnel. The manufacturer cannot be held liable for any damage caused by a faulty installation.
CHAP 4 - DESCRIPTION OF THE MACHINE 4.1 Technical features TECHNICAL DATA U.M. F100 T F100 T/L F120 T F120 T/L F200 T F200 T/L Width 1006 1018 Length Height Internal width Internal length Internal height Total capacity 0.16 0.20...
4.3.1 Regulating thermostat The regulator thermostat is a device to control the air temperature in the display cabinet. When the temperature drops under the values set by the user, the thermostat disconnects the power supply. The power supply will come back on automatically by increasing the temperature. CHAP 5 - PUTTING INTO OPERATION 5.1 Description of operations 1.
CHAP 6 - MALFUNCTIONING 6.1 Troubles during operation CAUTION: For all the operations described below, disconnect the display cabinet from the mains and address to specialized personnel who have a sufficient knowledge of the functions of the different parts and of the precautions to be taken. Below are listed some possible malfunctioning and the likely cause and remedy.
Remove all the containers that may be in the display cabinet. Use a soft damp cloth and then dry. To clean the stainless steel do not use iron wool, iron brushes or scrapers since they can deposit ferrous particles that by oxidizing lead to rust. To remove hardened residues, use wooden or plastic spatulas, or stainless steel wool.
3. Remove the insulating cover by unscrewing the four screws. 4. Replace the thermometer positioning the sensor in the same position and close it all back up. 7.2.5 Replacing the neon To replace the neon inside the cabinet it is necessary to carry out the following operations: 1.
Page 11
1. Left sliding door 12. Brass pin for sliding doors 22. Thermostat 2. Right sliding door 13. Structure 23. Upper housing 3. Traction spring for sliding doors 14. Defrosting timer 24. Rear housing 4. Rail support 15. Refrigerating unit 25. Right housing 5.
Page 12
IN - lighting switch N1 - internal lighting lamp IG - refrigerating unit switch GR - refrigerating unit TR - regulator thermostat Figure 4 - Electrical circuit A. Indicator defrosting duration B. Defrosting duration C. Indicator fan delay time D. Fan delay time E.