SPECIFICATIONS

Maximum Liquid Pressure: 150 psi (10.5 kg/cm
Liquid Temperature Range (T
Ambient Temperature Range (T
Electrical Enclosure Rating: Nema Type 1 (IP 21)
Maximum Velocity: 10ft/sec (3M/sec)
Pipe Connection Thread Size:

ELECTRICAL RATINGS

Motor Switch Rating (Amperes)
Voltage
Full Load
120 VAC
7.4
240 VAC
3.7
Models that meet CE Conformance:
FS5-J-3/4-E
FS5-J-1-E
• This Control: is for continuous operations
is not electronic
has Type 1C action (micro interruption
on operation)
• LVD 73/23/EEC
• EMC 89/33/EEC
For applications with loads between 0.5 and 3.7 Amps,
power factors exceeding 0.65, an anticipated system
switch operation rate of less than once per 2.5 minutes,
and any one cycle greater than 3 seconds on and 3
seconds off.
2
): 32 - 250˚F (0 - 121˚C) (All models except "S")
L
32 - 225˚F (0 - 107˚C) ("S" models)
): 32 - 120˚F (0 - 49˚C)
S
3
/
" or 1" NPT (All models except "J")
4
3
/
" or 1" BSPT ("J" models)
4
Locked Rotor
Pilot Duty
44.4
125 VA at
120 or 240 VAC
22.2
50 or 60 cycles
2
)
CE Circuit Rating
7.4 (7.4)/120~
3.7 (3.7)/240~
For applications with loads 0.5 and 38mA, power
factors exceeding 0.65, an anticipated system
switch operation rate of less than once per 5 minutes,
and any one cycle greater than 3 seconds on and 3
seconds off.
Additional suppression may be required for applica-
tions outside these ranges.
• Declaration of Conformity
Available on request.
0.3/120=
0.15/240=

Advertisement