28
en | Installing multiple sets (stacking)
In a multi-stack configuration, it is possible to have a stack or a row of four-beam sets
assigned to Group A, with each stack also being assigned to a specific channel, channel M
(Master), 1, 2, or 3. A similar configuration is possible with a multiple stack configuration
assigned to Group B.
Channels 1, 2, and 3 emit beams only when Channel M (Master) is active. Channels 1, 2
and/or 3 emit beams only when connected to the Channel M stack through the use of a
"synchro" wire. Refer to Synchro wiring, page 29 for more details.
Group A and Group B channel selections
Group A
Group B
Notice!
In a multi-stack configuration, one row must be assigned as the Master (M) with each
corresponding stack assigned a different channel (1 to 3) and attached by synchro wiring.
Refer to the following tables for transmitter/receiver channel programming.
Group switch settings
Switch
1
Channel switch settings
Switch
2
3
Extra features switch settings
Switch
4
5
6
2016.02 | 03 | F.01U.303.478
Channel M (Master)
Channel 1
Channel 2
Channel 3
Channel M (Master)
Channel 1
Channel 2
Channel 3
Function
GROUP
M
OFF
OFF
FUNCTION
AND/OR Gate
BYPASS
LEVEL CHECK
Installation and Operation Guide
Available from A1 Security Cameras
www.a1securitycameras.com email: sales@a1securitycameras.com
OFF
A
Function
1
2
OFF
ON
ON
OFF
OFF
AND
OFF
LOWER BEAM
Photobeam 5000
ON
B
3
ON
ON
ON
OR
ON
UPPER BEAM
Bosch Security Systems, Inc.